Manufacturer |
N/A State® |
Tank Capacity |
N/A 50 gal189 L |
Maximum Input Power |
N/A 90 kW |
Approximate Shipping Weight |
N/A 221 lb100.2 kg |
Standard Input Power |
N/A 30 kW |
Input Power |
N/A 102390 BTU/hr |
Voltage |
N/A 208 V240 V277 V480 V |
Phase |
N/A Single Three |
Working Pressure |
N/A 150 psi160 psi |
Style |
N/A Statesman |
Size |
N/A C |
Type |
N/A Electric |
Industry Standards |
N/A ASHRAE/IESNA 90.1 ASME Certified CSA® Certified NEC UL® Listed |
Recovery at 30 ºF Temperature Rise |
N/A 410 gal/h |
Recovery at 40 ºF Temperature Rise |
N/A 308 gal/h |
Recovery at 50 ºF Temperature Rise |
N/A 246 gal/h |
Recovery at 60 ºF Temperature Rise |
N/A 205 gal/h |
Recovery at 70 ºF Temperature Rise |
N/A 176 gal/h |
Recovery at 80 ºF Temperature Rise |
N/A 154 gal/h |
Recovery at 90 ºF Temperature Rise |
N/A 137 gal/h |
Recovery at 100 ºF Temperature Rise |
N/A 123 gal/h |
Recovery at 110 ºF Temperature Rise |
N/A 112 gal/h |
Recovery at 120 ºF Temperature Rise |
N/A 103 gal/h |
Recovery at 130 ºF Temperature Rise |
N/A 95 gal/h |
Recovery at 140 ºF Temperature Rise |
N/A 88 gal/h |
Number of Immersion Heaters1 | N/A 2 |
Element Power |
N/A 15000 W |
Number of 50 A Contactors (208 V) |
N/A 2 |
Number of 50 A Contactors (240 V) |
N/A 2 |
Number of 50 A Contactors (480 V) |
N/A 1 |
Full Load Current Single Phase 208 V |
N/A 144.2 A |
Full Load Current Single Phase 240 V |
N/A 125 A |
Full Load Current Single Phase 277 V |
N/A 108.3 A |
Full Load Current Single Phase 480 V |
N/A 62.5 A |
Full Load Current Three Phase 208 V |
N/A 83.3 A |
Full Load Current Three Phase 240 V |
N/A 72.2 A |
Full Load Current Three Phase 480 V |
N/A 36.1 A |
Features |
N/A
Advanced Electronic Control. State’s new proprietary electronic water heater control provides precise + or - 1 ºF temperature control that is ideal for industrial and food service applications where exact temperatures of hot water are needed. iCOMM™ Compatible. Plain English Text - Animated icons display detailed operational and diagnostic information. Fault or Alert messages appear if an operational issue occurs. Element Sensing - Each element is constantly monitored and current on/off state is displayed, any element failure is reported and its exact location is shown. Eliminates guesswork, makes troubleshooting easy and helps keep the unit operating at maximum performance. Low Water Cut Off - Factory standard on-board low water cutoff uses a remote electronic immersion type probe to prevent energizing of the elements in the event of low water condition and eliminates accidental dry firing. Sequencing - Units with multiple element contactors are sequenced on with one-second delay between stages. Prevents high amp electrical loads from hitting the electric system all at once and provides a smoother operating unit. An adjustable modulating control is optional. Economy Mode Operation - Control system automatically lowers the operating set point by a programmed value during user-defined time periods. Seven-day clock may be programmed for night set back and/or weekend shutdown to reduce operating cost and save energy. Incoloy Immersion Heaters - Heavy-duty medium watt density elements have incoloy sheathing and prewired leads: provides excellent protection against oxidation and scaling. Input ranges from 3 kW to 90 kW available. Heavy Foam Insulated - All models meet the standby loss requirements of the U.S. Department of Energy and current edition of AHRAE/IESNA 90.1. Glasslined Tank - Glass coating provides superior protection against corrosion and is bonded to all inner tank surfaces at 1600 ºF. ASME Tank Construction - 125 psi working pressure (65 thru 120 gallons), 150 psi working pressure (5 thru 50 gallons). Standard Voltages - 208, 240, and 480 volt single and three phase. Single phase 208 and 240 are convertible to three phase. All 208 and 240 volt at 24 kW and below are supplied phase convertible (single to three and vice versa). 277 volt single phase also available. Consult factory for 120 volt power circuit availability. Terminal Block - To accept copper or aluminum leads (on units with more than one contactor). 120 Volt Control Circuit - 120 volt control circuit powered by fused transformer. Magnetic Contactors - Heavy-duty UL rated for 100,000 cycles. Power Circuit Fusing (120 Amp Current Draw And Above) - Meets National Electric Code and UL requirements that water heaters must have internal fusing when current draw exceeds 120 amps. Simplified circuitry, color-coded for ease of service. Brass Drain Valve. Hinged control compartment door. CSA/ASME rated T& Prelief valve. |
Optional Equipment and Construction |
N/A
Stainless Steel Tank - Available for deionized water. Add a D to the end of the model prefix for use with deionized water. For example a SSE 100 would become a SSED 100. Please note: Stainless Steel units are for deionized water heating applications only! SSED models are not approved or certified for domestic potable water heating applications. To maintain warranty for domestic potable hot water heating applications use only the SSE glass lined models. 150 or 160 PSI Working Pressure - Available when required. Must be specified at time of order. Handhole Cleanout - 4"x 6" size. Combination Temperature/Pressure Gauge - Dial type combination gauge (shipped loose). |
Control Options |
N/A
Control Options Override Switches - A simple form of load control allows all or part of unit input to be controlled manually. Up to one override switch per contactor is available. Indicating/Pilot Lights - For indicating element operation and/or switch closure. Up to one indicating light available for each switch and/or contactor is available. Modulating Control - The first element on is the first element off. Not available on single element, single contactor units. Pressure Limit Switches - Both high and low pressure limit switches available. Power Circuit Fusing - Sub-divides internal circuitry with maximum of 60 amp fuses. Supplied as standard when required by NEC and UL. Alarm Horn - Horns may be furnished to warn of any condition in the heater for which sensors have been specified. Optional International Voltages - 380, 415, 575 and 600 volts three-phase available with Y connected elements. |