Manufacturer |
N/A Rheem® |
Input Power |
N/A 250000 BTU/hr |
Tank Capacity |
N/A 100 U.S. gal |
Minimum to Recovery Contents |
N/A 25 |
Maximum Working Pressure |
N/A 150 psi |
Blower Voltage |
N/A 120 V |
Blower Current |
N/A 1.5 A |
Approximate Shipping Weight |
N/A 860 lb390 kg |
Type |
N/A Liquid Propane Gas Natural Gas |
Size |
N/A C |
Style |
N/A Ventmaster™ |
Industry Standards |
N/A AHRI Certified® ASHRAE Standards CSA® Certified |
Side Clearance to Combustibles |
N/A 2 in51 mm |
Rear Clearance to Combustibles |
N/A 6 in153 mm |
Recovery at 40 ºF Temperature Rise |
N/A 606 U.S. gal/h |
Recovery at 22 ºC Temperature Rise |
N/A 2294 L/h |
Recovery at 50 ºF Temperature Rise |
N/A 485 U.S. gal/h |
Recovery at 28 ºC Temperature Rise |
N/A 1835 L/h |
Recovery at 60 ºF Temperature Rise |
N/A 404 U.S. gal/h |
Recovery at 33 ºC Temperature Rise |
N/A 1529 L/h |
Recovery at 70 ºF Temperature Rise |
N/A 346 U.S. gal/h |
Recovery at 39 ºC Temperature Rise |
N/A 1311 L/h |
Recovery at 80 ºF Temperature Rise |
N/A 303 U.S. gal/h |
Recovery at 45 ºC Temperature Rise |
N/A 1147 L/h |
Recovery at 90 ºF Temperature Rise |
N/A 269 U.S. gal/h |
Recovery at 50 ºC Temperature Rise |
N/A 1020 L/h |
Recovery at 100 ºF Temperature Rise |
N/A 242 U.S. gal/h |
Recovery at 56 ºC Temperature Rise |
N/A 918 L/h |
Recovery at 110 ºF Temperature Rise |
N/A 220 U.S. gal/h |
Recovery at 61 ºC Temperature Rise |
N/A 834 L/h |
Recovery at 120 ºF Temperature Rise |
N/A 202 U.S. gal/h |
Recovery at 67 ºC Temperature Rise |
N/A 765 L/h |
Recovery at 130 ºF Temperature Rise |
N/A 186 U.S. gal/h |
Recovery at 72 ºC Temperature Rise |
N/A 706 L/h |
Recovery at 140 ºF Temperature Rise |
N/A 173 U.S. gal/h |
Recovery at 78 ºC Temperature Rise |
N/A 655 L/h |
Maximum Delivery at 100 ºF (5 Minutes) |
N/A 90 U.S. gal |
Maximum Delivery at 37.7 ºC (5 Minutes) |
N/A 341 L |
Maximum Delivery at 100 ºF (10 Minutes) |
N/A 110 U.S. gal |
Maximum Delivery at 37.7 ºC (10 Minutes) |
N/A 418 L |
Maximum Delivery at 100 ºF (15 Minutes) |
N/A 131 U.S. gal |
Maximum Delivery at 37.7 ºC (15 Minutes) |
N/A 494 L |
Maximum Delivery at 100 ºF (20 Minutes) |
N/A 151 U.S. gal |
Maximum Delivery at 37.7 ºC (20 Minutes) |
N/A 571 L |
Maximum Delivery at 100 ºF (30 Minutes) |
N/A 191 U.S. gal |
Maximum Delivery at 37.7 ºC (30 Minutes) |
N/A 724 L |
Maximum Delivery at 100 ºF (45 Minutes) |
N/A 252 U.S. gal |
Maximum Delivery at 37.7 ºC (45 Minutes) |
N/A 953 L |
Maximum Delivery at 100 ºF (60 Minutes) |
N/A 312 U.S. gal |
Maximum Delivery at 37.7 ºC (60 Minutes) |
N/A 1183 L |
Front Inlet/Outlet Water Connection |
N/A 2 in51 mm |
Rear Side Water Connection |
N/A 2 in51 mm |
Features and Benefits |
N/A
Ventmaster™ power direct vent commercial water heaters provide outside air for combustion, which eliminates negative air pressure issues in tight construction. Models are available in 199,900 and 250,000 BTU/hr, with a maximum temperature setting of 180 degrees Fahrenheit. Thermal Efficiency Meets or exceeds a minimum of 80% non-condensing). System Sentinel™ LED Diagnostic System Our exclusive diagnostic system, with glowing LED lights, verifies system operation sequence by sequence. Patented Technology Patented multi-flue tank design has a proprietary steel formulation with two coats of high temperature porcelain enamel to maximize corrosion resistance. This results in a superior, long lasting heat exchanger. Integral Automatic Blower The 120 Volt blower assists in quietly discharging combustion gases. Gas Control System The control system has a fully adjustable thermostat from 100º F to 180 ºF. The 24 volt combination gas valve includes main gas pressure regulation and an on-off manual valve. The 120/24 volt transformer and high limit cut-out allow for accurate and safe temperature settings. Easier, Less Costly Venting Installs with 3" or 4" Schedule 40 PVC pipe; no masonry or metal vent chimney is required. Can be installed virtually anywhere. Maximum vent length is 50 feet. Base Rail Design Provides better handling when moving the unit. Full-port, Full-flow Drain Valve Factory installed brass drain valve allows for faster draining and servicing. Direct Spark-to-Pilot Ignition System Less fuel consumption. Hand-hole Cleanout Easy removal of sediment deposits. |
Testing and Certifications |
N/A
Altitude Certification Standard models certified up to 2,000 feet; high altitude models available up to 8,000 feet CSA/ASME Rated T&P Valve Factory installed relief valve |
General Information |
N/A
Efficiency All models tested according to ANSI test procedures, and meet or exceed the thermal efficiency and standby loss requirements of ASHRAE standard (EPact). Also exceeds energy efficiency codes of all states including California Energy Commission (CEC). Safety and Construction Design certified by CSA®: For operation at 180 degrees; meets all safety and construction requirement of ANSI Z21.10.3; as an automatic storage or instantaneous water heater; as an automatic circulating tank water heater; and for operation on combustible floors and in alcove installations. All models are North Carolina Code compliant. Certified for 150 PSI maximum working pressure (160 PSI for ASME models). Optional ASME Construction ASME construction is available on designated models. |