Manufacturer |
N/A Rheem® |
Tank Capacity |
N/A 82 gal |
Input Power |
N/A 156000 BTU/hr |
Thermal Efficiency |
N/A 80 % |
Standard Approximate Shipping Weight |
N/A 490 lb |
Voltage |
N/A 120 V |
Current |
N/A 1.5 A |
Working Pressure |
N/A 150 psi |
Style |
N/A Universal™ Ultra-Low NOx |
Size |
N/A C |
Type |
N/A Natural Gas |
Industry Standards |
N/A ANSI Z-21.10.3 - CSA 4.3 ASHRAE Standards 90.1b-2001 CSA® Certified |
Recovery at 40 ºF Temperature Rise |
N/A 378 gal/h |
Recovery at 50 ºF Temperature Rise |
N/A 303 gal/h |
Recovery at 60 ºF Temperature Rise |
N/A 252 gal/h |
Recovery at 70 ºF Temperature Rise |
N/A 216 gal/h |
Recovery at 80 ºF Temperature Rise |
N/A 189 gal/h |
Recovery at 90 ºF Temperature Rise |
N/A 168 gal/h |
Recovery at 100 ºF Temperature Rise |
N/A 151 gal/h |
Recovery at 110 ºF Temperature Rise |
N/A 138 gal/h |
Recovery at 120 ºF Temperature Rise |
N/A 126 gal/h |
Recovery at 130 ºF Temperature Rise |
N/A 116 gal/h |
Recovery at 140 ºF Temperature Rise |
N/A 108 gal/h |
First Time Delivery at 100 ºF (5 Minutes) |
N/A 70 gal |
First Time Delivery at 100 ºF (10 Minutes) |
N/A 83 gal |
First Time Delivery at 100 ºF (15 Minutes) |
N/A 95 gal |
First Time Delivery at 100 ºF (20 Minutes) |
N/A 108 gal |
First Time Delivery at 100 ºF (30 Minutes) |
N/A 133 gal |
First Time Delivery at 100 ºF (45 Minutes) |
N/A 171 gal |
First Time Delivery at 100 ºF (60 Minutes) |
N/A 209 gal |
First Time Delivery at 100 ºF (120 Minutes) |
N/A 360 gal |
First Time Delivery at 100 ºF (180 Minutes) |
N/A 511 gal |
Minimum to Recovery Contents |
N/A 33 |
Side Clearance to Combustibles |
N/A 2 in |
Rear Clearance to Combustibles |
N/A 2 in |
Top Clearance to Combustibles |
N/A 12 in |
Features and Benefits |
N/A
The tighter the commercial retrofit, the more you will appreciate how the Universal™'s compact size and multiple water connections simplify ultra low NOx installations. Choose from 80% thermal efficiency models that range from 125,000-399,900 Btu/h and 82% thermal efficiency models that range from 199,900 - 270,000 Btu/h. All models have a maximum temperature setting of 180 ºF. Space Saver Design The short heights and narrow jacket diameters, plus the top, front and rear water inlets/outlets offer the ultimate in installation flexibility. System Sentinel™ LED Diagnostic System Our exclusive diagnostic system, with glowing LED lights, verifies system operation sequence by sequence. Patented Technology Universal’s proprietary steel formulation, patented multi-flue design, combined with two coats of porcelain enamel, results in a superior heat exchanger design. Ultra Low NOx Burner The power assist burner design incorporates stainless steel multi-port burner tubes for long term low NOx performance, less than 14 ng/J. A sight glass allows for burner observation. The entire design is removable and it is highly resistant to the effects of negative air pressure common in modern commercial buildings. Base Rail Design Provides for better handeling when moving and positioning unit. Low Profile Automatic Flue Damper Low profile damper minimizes overall product height. Heavy duty vent hood supports are designed to withstand the rigors of installation. Full-port, Full-flow Drain Valve Factory installed brass drain valve allows for faster draining and servicing. Direct Spark-to-Pilot Ignition System Energy saving ignition that ignites pilot only when there is a call for heat. Patented Anode Rods Anode design utilizes multiple magnesium rods to ensure corrosion resistance for a long tank life. |
General Information |
N/A
Efficiency All models tested according to ANSI test procedures, and meet or exceed the thermal efficiency and standby loss requirements of ASHRAE standard (EPact). Also exceeds energy efficiency codes of all states including California Energy Commission (CEC). Safety and Construction Design certified by CSA: For operation at 180 degrees; meets all safety and construction requirement of ANSI Z-21.10.3; as an automatic storage or instantaneous water heater; as an automatic circulating tank water heater; and for operation on combustible floors and in alcove installations. Certified for 150 PSI maximum working pressure. |