Manufacturer |
N/A Rheem® |
Tank Capacity |
N/A 90 gal341 L |
Input Power |
N/A 680000 BTU/hr |
Type |
N/A Liquid Propane Gas |
Thermal Efficiency |
N/A 80 % |
Front Side Water Connection |
N/A 2 in51 mm |
Rear Side Water Connection |
N/A 2 in51 mm |
Standard Approximate Shipping Weight |
N/A 905 lb411 kg |
ASME Approximate Shipping Weight |
N/A 945 lb429 kg |
Voltage |
N/A 120 V |
Current |
N/A 2.5 A |
Working Pressure |
N/A 160 psi |
Style |
N/A Xtreme™ Low NOx |
Size |
N/A C |
Industry Standards |
N/A ANSI Z-21.10.3 - CSA 4.3 ASHRAE Standards 90.1-1999 ASME Certified CSA® Certified UL® Listed |
Recovery at 40 ºF Temperature Rise |
N/A 1649 U.S. gal/h |
Recovery at 22 ºC Temperature Rise |
N/A 6240 L/h |
Recovery at 50 ºF Temperature Rise |
N/A 1319 U.S. gal/h |
Recovery at 28 ºC Temperature Rise |
N/A 4992 L/h |
Recovery at 60 ºF Temperature Rise |
N/A 1099 U.S. gal/h |
Recovery at 33 ºC Temperature Rise |
N/A 4160 L/h |
Recovery at 70 ºF Temperature Rise |
N/A 942 U.S. gal/h |
Recovery at 39 ºC Temperature Rise |
N/A 3565 L/h |
Recovery at 80 ºF Temperature Rise |
N/A 824 U.S. gal/h |
Recovery at 45 ºC Temperature Rise |
N/A 3120 L/h |
Recovery at 90 ºF Temperature Rise |
N/A 733 U.S. gal/h |
Recovery at 50 ºC Temperature Rise |
N/A 2773 L/h |
Recovery at 100 ºF Temperature Rise |
N/A 659 U.S. gal/h |
Recovery at 56 ºC Temperature Rise |
N/A 2496 L/h |
Recovery at 110 ºF Temperature Rise |
N/A 599 U.S. gal/h |
Recovery at 61 ºC Temperature Rise |
N/A 2269 L/h |
Recovery at 120 ºF Temperature Rise |
N/A 550 U.S. gal/h |
Recovery at 67 ºC Temperature Rise |
N/A 2080 L/h |
Recovery at 130 ºF Temperature Rise |
N/A 507 U.S. gal/h |
Recovery at 72 ºC Temperature Rise |
N/A 1920 L/h |
Recovery at 140 ºF Temperature Rise |
N/A 471 U.S. gal/h |
Recovery at 78 ºC Temperature Rise |
N/A 1783 L/h |
Maximum Delivery at 100 ºF (5 Minutes) |
N/A 118 U.S. gal |
Maximum Delivery at 55.6 ºC (5 Minutes) |
N/A 446 L |
Maximum Delivery at 100 ºF (10 Minutes) |
N/A 173 U.S. gal |
Maximum Delivery at 55.6 ºC (10 Minutes) |
N/A 654 L |
Maximum Delivery at 100 ºF (15 Minutes) |
N/A 228 U.S. gal |
Maximum Delivery at 55.6 ºC (15 Minutes) |
N/A 862 L |
Maximum Delivery at 100 ºF (20 Minutes) |
N/A 283 U.S. gal |
Maximum Delivery at 55.6 ºC (20 Minutes) |
N/A 1070 L |
Maximum Delivery at 100 ºF (30 Minutes) |
N/A 393 U.S. gal |
Maximum Delivery at 55.6 ºC (30 Minutes) |
N/A 1486 L |
Maximum Delivery at 100 ºF (45 Minutes) |
N/A 558 U.S. gal |
Maximum Delivery at 55.6 ºC (45 Minutes) |
N/A 2110 L |
Maximum Delivery at 100 ºF (60 Minutes) |
N/A 722 U.S. gal |
Maximum Delivery at 55.6 ºC (60 Minutes) |
N/A 2886 L |
Maximum Delivery at 100 ºF (120 Minutes) |
N/A 1382 U.S. gal |
Maximum Delivery at 55.6 ºC (120 Minutes) |
N/A 5230 L |
Maximum Delivery at 100 ºF (180 Minutes) |
N/A 2041 U.S. gal |
Maximum Delivery at 55.6 ºC (180 Minutes) |
N/A 7726 L |
Minimum to Recovery Contents |
N/A 8 |
Side Clearance to Combustibles |
N/A 4 in102 mm |
Rear Clearance to Combustibles |
N/A 4 in102 mm |
Top Clearance to Combustibles |
N/A 12 in305 mm |
Minimum Front Clearance Size |
N/A 18 in457 mm |
Features and Benefits |
N/A
Xtreme™ is an advanced line of fast recovery commercial gas water heaters. These products can deliver up to 756 gallons per hour at 100 degree F rise. The small jacket diameter makes it a popular choice for retro fits and it is a versatile choice for new construction. Models range from 500,000-715,000 Btu/h, with a maximum temperature setting of 180 degrees Fahrenheit. Space Saver Design Xtreme™ maximizes installation adaptability by offering models with front and rear inlet/outlet water connections. Short heights and small jacket diameters result in greater installation flexibility. System Sentinel™ LED Diagnostic System Our exclusive diagnostic system, with glowing LED lights, verifies system operation sequence by sequence. Patented Multi-Flue Tank Design Proprietary steel formulation, patented multi-flue design, and two coats of high temperature porcelain enamel maximize corrosion resistance and result in a superior heat exchanger design. Automatic Flue Damper Low profile design minimizes overall product height. Heavy duty vent hood supports are designed to withstand rigors of installation. Specialized Burner Assembly Each model features five premix burners mounted into a metal face plate and sealed with a Fluoroelastomer gasket. Patented "quick release" manifold for easier service. Direct Spark-to-Pilot Ignition System Energy saving ignition that ignites pilot only when there is a call for heat. Round Premix Burners Precision burners are formed from high chromium stainless steel. Full-port, Full-flow Drain Valve Factory installed brass drain valve allows for faster draining and servicing. Anode Rods Patented design utilizes multiple magnesium rods to ensure long life and corrosion resistance. Insulation Sag and moisture proof fiberglass insulation surrounds the storage tank to minimize heat loss. Hand-Hole Cleanout It's perfect for removal of lime/sediment deposits. Manual Reset High Limit All models are factory equipped with a manual reset high limit to meet the code requirements of many states. Gas Control System The fully adjustable thermostat ranges from 100 ºF to 180 ºF and 24 volt combination gas valve includes main gas pressure regulation, On-Off manual valve, 120/24 volt transformer, and high limit temperature cut-out. |
General Information |
N/A
Efficiency All models have been tested according to ANSI test procedures, and exceed the thermal efficiency and standby loss requirements of current ASHRAE standards (Part of the Federally mandated Energy Policy Act (EPact)). Also exceeds energy efficiency codes of all states. Safety and Construction These products are design certified by U.L.:
|
Testing and Certifications |
N/A
Altitude Certifications Standard Natural and LP models are certified up to 2,000 feet. High altitude models, 8,000 feet CSA/ASME Rated T&P Valve Factory installed relief valve |
Note |
N/A
Recovery ratings are based on thermal efficiencies obtained in a CSA certified laboratory. Recovery rate shown on the rating plate (80%) Thermal Efficiency in accordance with ANSI Z21.10.3 labeling requirements. (A) indicates available ASME model. All models require a 120 V power source. (A) Suffix indicates ASME tank construction available. Allow a minimum of 18" (457 mm) front clearance for servicing. 2.5 Amps. |