Manufacturer |
N/A A. O. Smith® |
Approximate Capacity |
N/A 65 gal246 L |
Input Rating |
N/A 55000 BTU/hr65000 BTU/hr18 kW/hr19 kW/hr |
Type |
N/A Liquid Propane Gas Natural Gas |
Approximate Shipping Weight |
N/A 240 lb108.9 kg |
Maximum Working Pressure |
N/A 150 psi |
Maximum Gas Inlet Pressure |
N/A 14 inWc |
Industry Standards |
N/A ASHRAE/IESNA 90.1 ASME Certified CSA® Certified UL® Listed |
Recovery at 30 ºF Temperature Rise |
N/A 200 gal/h |
Recovery at 40 ºF Temperature Rise |
N/A 150 gal/h |
Recovery at 50 ºF Temperature Rise |
N/A 120 gal/h |
Recovery at 60 ºF Temperature Rise |
N/A 100 gal/h |
Recovery at 70 ºF Temperature Rise |
N/A 86 gal/h |
Recovery at 80 ºF Temperature Rise |
N/A 75 gal/h |
Recovery at 90 ºF Temperature Rise |
N/A 67 gal/h |
Recovery at 100 ºF Temperature Rise |
N/A 60 gal/h |
Recovery at 110 ºF Temperature Rise |
N/A 54 gal/h |
Recovery at 120 ºF Temperature Rise |
N/A 50 gal/h |
Recovery at 130 ºF Temperature Rise |
N/A 46 gal/h |
Recovery at 140 ºF Temperature Rise |
N/A 43 gal/h |
Recovery at 17 ºC Temperature Rise |
N/A 758 L/h |
Recovery at 22 ºC Temperature Rise |
N/A 569 L/h |
Recovery at 28 ºC Temperature Rise |
N/A 455 L/h |
Recovery at 33 ºC Temperature Rise |
N/A 379 L/h |
Recovery at 39 ºC Temperature Rise |
N/A 326 L/h |
Recovery at 45 ºC Temperature Rise |
N/A 284 L/h |
Recovery at 50 ºC Temperature Rise |
N/A 254 L/h |
Recovery at 56 ºC Temperature Rise |
N/A 227 L/h |
Recovery at 61 ºC Temperature Rise |
N/A 205 L/h |
Recovery at 67 ºC Temperature Rise |
N/A 190 L/h |
Recovery at 72 ºC Temperature Rise |
N/A 174 L/h |
Recovery at 78 ºC Temperature Rise |
N/A 163 L/h |
Features |
N/A
All models meet the thermal efficiency and standby loss requirements of the U. S. Department of Energy and Current Edition ASHRAE/IESNA 90.1. Glass lined Tank - Maximizes tank life. Fully Automatic Controls with Safety Shutoff - Accurate, dependable control system requires no electric connections. Fixed automatic gas shutoff device for added safety. Not recommended for 180 ºF sanitizing. Heavy Gauge Steel Jacket - Finished with baked enamel over bonderized undercoat. Foam Insulation - Saves fuel, helps reduce standby heat loss. Low NOx - Complies with Texas and other districts requirements for NOx emissions less than 40 ng/j. Easy-to-Install - Completely factory-assembled. Only gas, water and vent connections need be made. All connections are located in front and top of heaters for ease of installation and service. Draft Diverter - Low profile diverter furnished as standard equipment. Handhole Cleanout - On models BT-80 & BT-100. Allows easy tank cleaning. |
Other Features |
N/A
|