Manufacturer |
N/A American Standard® |
Tank Capacity |
N/A 100 gal |
Input Power |
N/A 300000 BTU |
Type |
N/A Natural Gas |
Thermal Efficiency |
N/A 80 % |
Size |
N/A C |
Test Pressure |
N/A 300 psi |
Working Pressure |
N/A 150 psi |
Industry Standards |
N/A ANSI Z-21.10.3 - CSA 4.3 ASHRAE Standards 90.1-1999 ASME Certified NSF |
Recovery at 40 ºF Temperature Rise |
N/A 727 gal/h |
Recovery at 50 ºF Temperature Rise |
N/A 582 gal/h |
Recovery at 60 ºF Temperature Rise |
N/A 485 gal/h |
Recovery at 70 ºF Temperature Rise |
N/A 416 gal/h |
Recovery at 80 ºF Temperature Rise |
N/A 364 gal/h |
Recovery at 90 ºF Temperature Rise |
N/A 323 gal/h |
Recovery at 100 ºF Temperature Rise |
N/A 291 gal/h |
Recovery at 110 ºF Temperature Rise |
N/A 265 gal/h |
Recovery at 120 ºF Temperature Rise |
N/A 242 gal/h |
Recovery at 130 ºF Temperature Rise |
N/A 224 gal/h |
Recovery at 140 ºF Temperature Rise |
N/A 208 gal/h |
Storage Capacity |
N/A 100 U.S. gal |
One Hour Recovery at 100 ºF Temperature Rise |
N/A 291 gal/h |
Maximum Hot Water Delivery (1 Hour) |
N/A 361 L |
Maximum Hot Water Delivery (2 Hours) |
N/A 652 L |
Maximum Hot Water Delivery (3 Hours) |
N/A 943 L |
Maximum Hot Water Delivery Recovery at 100 ºF Temperature Rise |
N/A 4.9 g/min |
Testing and Certifications |
N/A
|
Features |
N/A
|
Warranty |
N/A
|
Note |
N/A
This water heater meets the requirements of ASHRAE 90.1-1999 and meets or exceeds the thermal efficiency and standby loss requirements of california and other states recognizing ASHRAE. Recovery rate indicated on heater rating plate is based on 75% (76%) thermal efficiency according to CSA (ANSI, Z.21.10.3). Manufacturer reserves the right to make product changes and/or improvements with or without notice. |