Manufacturer |
N/A Bradford White® |
Capacity |
N/A 400 gal |
Maximum Load Power |
N/A 360 kW |
Approximate Shipping Weight |
N/A 1750 lb |
Input Power |
N/A 60 kW |
Recovery at 100 ºF Temperature Rise |
N/A 246 gal/h |
Equivalent Power |
N/A 204720 BTU/hr |
Maximum Number of Elements |
N/A 4 |
Size of Element |
N/A 15 kW |
Number of Contactors (208, 240) |
N/A 12 |
Number of Contactors (380, 415, 480) |
N/A 6 |
Suggested Control Steps (208, 240) |
N/A 4 |
Suggested Control Steps (380, 415, 480) |
N/A 3 |
Voltage |
N/A 208 V240 V380 V415 V480 V |
Phase |
N/A Single Three |
Style |
N/A Brute Vertical Square & Horizontal Square |
Size |
N/A C |
Type |
N/A Electric |
Industry Standards |
N/A ASHRAE 90.1b-1992 ASME Certified UL® Listed |
Full Load Current Single Phase 208 V |
N/A 289 A |
Full Load Current Single Phase 240 V |
N/A 250 A |
Full Load Current Three Phase 208 V |
N/A 167 A |
Full Load Current Three Phase 240 V |
N/A 144 A |
Full Load Current Three Phase 380 V |
N/A 91 A |
Full Load Current Three Phase 415 V |
N/A 83 A |
Full Load Current Three Phase 480 V |
N/A 73 A |
Standard Equipment Features |
N/A
Energy-Saving Performance - A heavy blanket of high density fiberglass insulation is used to meet the demanding ASHRAE 90.1b 1992 standard for minimizing heat loss. This requirement, allowing a maximum 4 watts per square foot of tank surface energy loss, offers big savings and operating efficiency. Magnetic Contactors with Immersion Thermostats - 120 volt control circuit with built in transformer. Elements are thermostatically controlled in 54 KW (max) increments.. Low Watt Density Incoloy Elements - Incoloy elements are used by Bradford White because of their many superior characteristics to copper-sheathed elements in rigorous water heating applications. This tough alloy successfully resists the effects of prolonged high operating temperatures, hard water, acids, corrosion, and thermal shock. Their nominally higher initial cost is more than offset by much longer life expectancies and reduced service and replacement labor costs. Incoloy elements are designed to “burn in air” to prevent failures caused by water void. Internal Fusing - All elements and circuits are fused in 48 amp. increments, providing complete electrical protection. Cartridge type fuses are rated at 200,000 ampere interrupting capacity. Glass-Lined Tank - Vitreous glass is applied to the inside surface of the steel tank and fired to 1600 ºF. (All models are constructed in accordance with the ASME code and approved for 125 PSI working pressure.) Built-in Safety Drain Pan - All models feature a built-in, sealed drain pan system...complete with a 3/4" drain connection. This assists in protecting against water damage from tank or component leakage. Not available on round models. Magnesium Tank Saver - provides anodic protection against corrosion of the tank due to electrolysis. Galvanized Jacket - The heavy 16-gauge steel jacket is galvanized on both sides and beautifully finished in durable acrylic enamel. This combines attractive appearance with maximum protection. Full-Length Hinged Door with Key Lock - Quality requires full-length hinged doors for ease of inspection and maintenance. Key Door Lock provides additional safety and security at no extra charge. Temperature and Pressure Relief Valve - Factory provided ASME rated relief valve protects against excessive temperature and/or pressure buildup within the tank. Terminal Block Connections - Easy and safe wiring connections are made possible by factory installed terminal blocks. 180 ºF Temperature Operation - Every Electric Brute Heater is approved for 180 ºF operation for sanitizing and other high-temperature requirements. Hand Hole Cleanout - Provides easy access to the heater interior for inspection and cleaning. Channel iron skid base - Available for 250 gallons and larger. |
Optional Equipment Features |
N/A
Low Water Cut Off - Prevents energizing of the heater when not filled with water or upon low water condition. Pilot Lights - Monitor on/off cycle for each contactor. Manual Limiting Switches - With indicating lights - permits manual limitation of heating input by switching off current to each contactor. Solid State Modulating Control (Electronic Sequencer) - Modulates power input and balances load to demand. Contactors are staged automatically and sequentially to equalize element usage. Unit reprograms to off position on power failure. (Available only for 36 KW or higher). Alarm Bell - Warns of various control failures. Shunt Trip Disconnect (Separate mounting - Field Installed) - Provides maximum protection by interrupting all power to the system in the event of a control sensed malfunction or overcurrent. Low or High Pressure Switch - Turns off control circuit when water pressure drops below a set minimum, or above a set maximum. Time Clock (Separate mounting - Field Installed) - To control off/on cycles of the heater as programmed by the owner or electric utility requirements. 7 day or 24 hour). Safety Door Interlock - Prevents opening of access door while heater is energized. Temperature and Pressure Gauges - Jacket mounted for convenient viewing. Man Hole - Provides means to easily remove sediment from the heater. Working pressure - 150 PSI ASME construction. |
Testing and Certifications |
N/A UL Listed - All models are listed by Underwriters Laboratories, Inc. as commercial electric water heaters. This assures competent design and proper testing. |