Manufacturer |
N/A A. O. Smith® |
Capacity |
N/A 98 gal |
Type |
N/A Liquid Propane Gas Natural Gas |
Input Power |
N/A 90000 BTU/hr26.4 kW |
Manifold Pressure |
N/A For Liquid Propane Gas: 2.49 kPaFor Natural Gas: 1.12 kPaFor Liquid Propane Gas: 10 inWcFor Natural Gas: 4.5 inWc |
Maximum Gas Supply Pressure |
N/A 14 inWc3.48 kPa |
Minimum Supply Pressure for Natural Gas |
N/A 1.24 kPa5 in |
Minimum Supply Pressure for Liquid Propane Gas |
N/A 11 inWc2.74 kPa |
Industry Standards |
N/A ANSI Z-21.10.3 - CSA 4.3 ASHRAE/IESNA 90.1 |
Recovery at 30 ºF Temperature Rise |
N/A 291 gal/h |
Recovery at 36 ºF Temperature Rise |
N/A 242 gal/h |
Recovery at 40 ºF Degree Rise |
N/A 218 gal/h |
Recovery at 50 ºF Temperature Rise |
N/A 175 gal/h |
Recovery at 54 ºF Temperature Rise |
N/A 162 gal/h |
Recovery at 60 ºF Temperature Rise |
N/A 145 gal/h |
Recovery at 70 ºF Temperature Rise |
N/A 125 gal/h |
Recovery at 72 ºF Temperature Rise |
N/A 121 gal/h |
Recovery at 80 ºF Temperature Rise |
N/A 109 gal/h |
Recovery at 90 ºF Temperature Rise |
N/A 97 gal/h |
Recovery at 100 ºF Temperature Rise |
N/A 87 gal/h |
Recovery at 108 ºF Temperature Rise |
N/A 81 gal/h |
Recovery at 110 ºF Temperature Rise |
N/A 79 gal/h |
Recovery at 120 ºF Temperature Rise |
N/A 73 gal/h |
Recovery at 126 ºF Temperature Rise |
N/A 69 gal/h |
Recovery at 130 ºF Temperature Rise |
N/A 67 gal/h |
Recovery at 140 ºF Temperature Rise |
N/A 62 gal/h |
Recovery at 17 ºC Temperature Rise |
N/A 1104 L/h |
Recovery at 20 ºC Temperature Rise |
N/A 915 L/h |
Recovery at 23 ºC Temperature Rise |
N/A 825 L/h |
Recovery at 28 ºC Temperature Rise |
N/A 662 L/h |
Recovery at 30 ºC Temperature Rise |
N/A 613 L/h |
Recovery at 33 ºC Temperature Rise |
N/A 548 L/h |
Recovery at 39 ºC Temperature Rise |
N/A 473 L/h |
Recovery at 40 ºC Temperature Rise |
N/A 457 L/h |
Recovery at 44 ºC Temperature Rise |
N/A 412 L/h |
Recovery at 50 ºC Temperature Rise |
N/A 367 L/h |
Recovery at 56 ºC Temperature Rise |
N/A 329 L/h |
Recovery at 60 ºC Temperature Rise |
N/A 306 L/h |
Recovery at 61 ºC Temperature Rise |
N/A 299 L/h |
Recovery at 67 ºC Temperature Rise |
N/A 276 L/h |
Recovery at 70 ºC Temperature Rise |
N/A 261 L/h |
Recovery at 72 ºC Temperature Rise |
N/A 253 L/h |
Recovery at 78 ºC Temperature Rise |
N/A 234 L/h |
Features |
N/A
The BTN-80 and BTN-100 are equipped with a factory-mounted blower that is pre-wired. This blower produces a pre-ignition draft of make-up air prior to burner ignition and provides more efficient control of heat and helps ensure an adequate supply of make-up air. Prior to ignition, the control proves a working draft. Factory-installed Blower
Glass Lined Tank
Optional Leg Kit To Meet Nsf Standard 5 (Part # 9006645005 BTN 80 & 100) Intelli-Vent™ is a registered trademark of Emerson Electric Company. |
Options |
N/A
Conservationist® Btn Options Optional Leg Kit to Meet NSF Standard 5 (Part # 9006645005 BTN 80 & 100) Intelli-Vent™ is a registered trademark of Emerson Electric Company. |
Testing and Certifications |
N/A
CSA® Certified and ASME Rated T&P Relief Valve Codes and Standards
|