Items State Titan® LV Large Volume Power Burner - Gas, Oil and Dual-Fuel Commercial Water Heaters
TPO 150 720 OEA
TPO Power Oil Large Volume Commercial Water Heater
State Titan® LV Large Volume Power Burner - Gas, Oil and Dual-Fuel Commercial Water Heaters
TPD 150 720 ONEA
TPD Power Dual-Fuel Large Volume Commercial Water Heater
State Titan® LV Large Volume Power Burner - Gas, Oil and Dual-Fuel Commercial Water Heaters
TPG 150 140 NEA
TPG Power Gas Large Volume Commercial Water Heater
State Titan® LV Large Volume Power Burner - Gas, Oil and Dual-Fuel Commercial Water Heaters
TPG 150 199 NEA
TPG Power Gas Large Volume Commercial Water Heater
State Titan® LV Large Volume Power Burner - Gas, Oil and Dual-Fuel Commercial Water Heaters
TPG 150 255 NEA
TPG Power Gas Large Volume Commercial Water Heater
Description N/A TPO - Oil Fired Models: No. 1 or 2 Oil
  • Multi-annular fuel containment combustor head
  • Available for firing light fuel oils including diesel
  • Oil ignition transformer
  • Integral 2-stage fuel unit
  • Squirrel cage blower
  • Oil safety valve
N/A TPD - Dual-Fuel Gas/Oil: Natural Gas or Propane & No. 1 or 2 Oil
  • Multi-annular fuel containment combustor head
  • Gas electric pilot and gas ignition transformer
  • Pilot and main pressure regulators
  • Air safety switch
  • Manual fuel selector switch
  • Integral 2-stage fuel unit
  • Squirrel cage blower
N/A N/A N/A
Manufacturer N/A State®
Nominal Storage Capacity N/A 145 U.S. gal N/A 145 U.S. gal N/A 150 U.S. gal N/A 150 U.S. gal N/A 150 U.S. gal
Input Power N/A 720000 BTU/hr N/A 720000 BTU/hr N/A 140000 BTU/hr N/A 199000 BTU/hr N/A 255000 BTU/hr
First Hour Rating N/A 5.1 gal N/A 5.1 gal N/A 256 gal N/A 313 gal N/A 367 gal
Recovery at 80 ºF Temperature Rise N/A 873 gal/h N/A 873 gal/h N/A 170 gal/h N/A 241 gal/h N/A 359 gal/h
Recovery at 100 ºF Temperature Rise N/A 698 gal/h N/A 698 gal/h N/A 136 gal/h N/A 193 gal/h N/A 247 gal/h
Recovery at 140 ºF Temperature Rise N/A 416 gal/h N/A 416 gal/h N/A 97 gal/h N/A 138 gal/h N/A 176 gal/h
Schematic N/A
Schematic Drawing for State Titan® LV Large Volume Power Burner - Gas, Oil and Dual-FuelCommercial Water Heaters (TPO)
N/A
Schematic Drawing for State Titan® LV Large Volume Power Burner - Gas, Oil and Dual-FuelCommercial Water Heaters (TPD)
N/A
Schematic Drawing for State Titan® LV Large Volume Power Burner - Gas, Oil and Dual-FuelCommercial Water Heaters (TPG)
N/A
Schematic Drawing for State Titan® LV Large Volume Power Burner - Gas, Oil and Dual-FuelCommercial Water Heaters (TPG)
N/A
Schematic Drawing for State Titan® LV Large Volume Power Burner - Gas, Oil and Dual-FuelCommercial Water Heaters (TPG)
Dimension A N/A 82-1/4 in
Dimension B N/A 14 in
Dimension C N/A N/A 1-1/4 in N/A 1/2 in N/A 1/2 in N/A 1/2 in
Dimension D N/A 27-3/4 in N/A 27-3/ 4 in N/A 27-3/4 in N/A 27-3/4 in N/A 27-3/4 in
Dimension E N/A 1-1/4 in
Dimension F N/A 36-1/2 in
Dimension G N/A 10 in N/A 10 in N/A 5 in N/A 6 in N/A 6 in
Dimension H N/A 57-1/2 in N/A 57-1/2 in N/A 47 in N/A 47 in N/A 47 in
Dimension J N/A 73 in
Shipping Weight with Burner N/A 1510 lb N/A 1510 lb N/A 1292 lb N/A 1292 lb N/A 1292 lb
Motor Power N/A 1/4 hp N/A 1/4 hp N/A 1/7 hp N/A 1/7 hp N/A 1/7 hp
Current N/A 4.6 A N/A 4.6 A N/A 2.5 A N/A 2.5 A N/A 2.5 A
Voltage N/A 120 V
Frequency N/A 60 Hz
Type N/A Gas N/A Gas N/A Natural Gas N/A Natural Gas N/A Natural Gas
Style N/A State Titan® Power Low NOx N/A State Titan® Power Low NOx N/A State Titan® Large Volume N/A State Titan® Large Volume N/A State Titan® Large Volume
Size N/A C
Industry Standards N/A ASHRAE/IESNA 90.1 ASME Certified CSA® Certified UL® Listed
Features N/A
  • Meets the thermal efficiency and standby loss requirements of U.S. Department of Energy and current edition of ASHRAE/IESNA 90.1.
  • UL - Entire unit UL listed (File No. MH11631).
  • Low Nox - Complies with Texas low NOx and Air Quality Management Districts with requirements of less than 30 ppm.
  • Glasslined Tank - Exclusive corrosion protection with glasslining on all interior surfaces. Multiple anodes provide even more corrosion protection.
  • ASME Construction Standard - 160 PSI working pressure on all models.
  • Power Gas Burner - Power burner has electronic flame safeguard control with intermittent spark ignition. Also included are main and pilot automatic gas valves plus gas pressure regulators, diaphragm air switch for proof of blower operation.
  • Fully Automatic Controls With Safety Shutoff - High temperature limit control (manual reset). CSA® Certified and ASME rated T&P Relief Valve. Hinged door control compartment for ease of access. Two thermostats, upper and lower, for accurate temperature control. Standard control is for 120 ºF - 180 ºF water service.
  • Jacket And Insulation - Heavy gauge steel with baked powder coat finish. Insulated with high-density foam insulation that meets or exceeds all required standards.
  • Factory Start-up Included - Required for activating warranty and assuring maximum operating performance.
Other Features N/A
  • Two layers of high temperature ceramic fiber insulation in combustion chamber
  • Flame inspection port opening
  • Mounted on rugged channel iron skids
  • Combination temperature and pressure gauge
  • Low water cutoff
  • ASME rated temperature and pressure relief valve
  • Barometric draft regulator
  • Two cleanout inspection openings
  • 120 volt control circuit
  • Drain valve
  • Removable lifting lugs
Note N/A Certified Minimum Installation Clearances to Combustibles:
  • Front: 18 inches
  • Back: 0 inches
  • Sides: 0 inches
  • Top: 5 inches
A clearance of 24 inches should be maintained from serviceable parts such as relief valve, power burner, drain valve and anodes (Anodes are located on side above cold water inlet).

State Titan TPO models are Category I appliances (Fan Assisted) and require a negative draft. These units should only be commonly vented with other Category I negative draft appliances per the latest addition of the National Fuel Gas Code. An approved/listed Type "B" venting material is recommended. A negative draft of -0.02" to -0.07 is required in the vent.
N/A Certified Minimum Installation Clearances to Combustibles:
  • Front: 18 inches
  • Back: 0 inches
  • Sides: 0 inches
  • Top: 5 inches
A clearance of 24 inches should be maintained from serviceable parts such as relief valve, power burner, drain valve and anodes (Anodes are located on side above cold water inlet).

State Titan TPD models are Category I appliances (Fan Assisted) and require a negative draft. These units should only be commonly vented with other Category I negative draft appliances per the latest addition of the National Fuel Gas Code. An approved/listed Type "B" venting material is recommended. A negative draft of -0.02" to -0.07 is required in the vent.
N/A Certified Minimum Installation Clearances to Combustibles:
  • Front: 18 inches
  • Back: 0 inches
  • Sides: 0 inches
  • Top: 5 inches
A clearance of 24 inches should be maintained from serviceable parts such as relief valve, power burner, drain valve and anodes (Anodes are located on side above cold water inlet).

Minimum gas supply pressure: 7 Inches W.C.
Maximum gas supply pressure: 13 Inches W.C.

TPG models are Category I appliances (Fan Assisted) and require a negative draft. These units should only be commonly vented with other Category I negative draft appliances per the latest addition of the National Fuel Gas Code. An approved/listed Type "B" venting material is recommended. A negative draft of -0.02" to -0.07 is required in the vent.
N/A Certified Minimum Installation Clearances to Combustibles:
  • Front: 18 inches
  • Back: 0 inches
  • Sides: 0 inches
  • Top: 5 inches
A clearance of 24 inches should be maintained from serviceable parts such as relief valve, power burner, drain valve and anodes (Anodes are located on side above cold water inlet).

Minimum gas supply pressure: 7 Inches W.C.
Maximum gas supply pressure: 13 Inches W.C.

TPG models are Category I appliances (Fan Assisted) and require a negative draft. These units should only be commonly vented with other Category I negative draft appliances per the latest addition of the National Fuel Gas Code. An approved/listed Type "B" venting material is recommended. A negative draft of -0.02" to -0.07 is required in the vent.
N/A Certified Minimum Installation Clearances to Combustibles:
  • Front: 18 inches
  • Back: 0 inches
  • Sides: 0 inches
  • Top: 5 inches
A clearance of 24 inches should be maintained from serviceable parts such as relief valve, power burner, drain valve and anodes (Anodes are located on side above cold water inlet).

Minimum gas supply pressure: 7 Inches W.C.
Maximum gas supply pressure: 13 Inches W.C.

TPG models are Category I appliances (Fan Assisted) and require a negative draft. These units should only be commonly vented with other Category I negative draft appliances per the latest addition of the National Fuel Gas Code. An approved/listed Type "B" venting material is recommended. A negative draft of -0.02" to -0.07 is required in the vent.