Print Back
Commercial Induced Draft Energy Saver Gas Water Heaters (D-65T-625-3NA)
Unit of Measure
Items Commercial Induced Draft Energy Saver Gas Water Heaters (D-65T-625-3NA)
D-65T-625-3NA
Commercial Induced Draft Energy Saver Gas Water Heaters
Image
D-65T-625-3XA
Commercial Induced Draft Energy Saver Gas Water Heaters
Image
D-80T-725-3NA
Commercial Induced Draft Energy Saver Gas Water Heaters
Image
D-80T-725-3XA
Commercial Induced Draft Energy Saver Gas Water Heaters
Manufacturer N/A Bradford White®
Capacity N/A 65 U.S. gal54 Imp. gal246 L N/A 65 U.S. gal54 Imp. gal246 L N/A 80 U.S. gal66 Imp. gal303 L N/A 80 U.S. gal66 Imp. gal303 L
Input Power N/A 625000 BTU/hr183 kW N/A 625000 BTU/hr183 kW N/A 725000 BTU/hr212.3 kW N/A 725000 BTU/hr212.3 kW
Type N/A Natural Gas N/A Liquid Propane Gas N/A Natural Gas N/A Liquid Propane Gas
Recovery at 40 ºF Temperature Rise N/A 1515 gal/h N/A 1515 gal/h N/A 1757 gal/h N/A 1757 gal/h
Recovery at 22 ºC Temperature Rise N/A 5734 gal/h N/A 5734 gal/h N/A 6652 gal/h N/A 6652 gal/h
Recovery at 100 ºF Temperature Rise N/A 606 gal/h N/A 606 gal/h N/A 703 gal/h N/A 703 gal/h
Recovery at 56 ºC Temperature Rise N/A 2294 gal/h N/A 2294 gal/h N/A 2661 gal/h N/A 2661 gal/h
Recovery at 140 ºF Temperature Rise N/A 433 gal/h N/A 433 gal/h N/A 502 gal/h N/A 502 gal/h
Recovery at 78 ºC Temperature Rise N/A 1638 gal/h N/A 1638 gal/h N/A 1901 gal/h N/A 1901 gal/h
Schematic N/A
Commercial Induced Draft Energy Saver Gas Water Heaters (D-65T-625-3NA) - 2
Floor to Heater Top A N/A 69-3/8 in1762 mm N/A 69-3/8 in1762 mm N/A 79-5/8 in2022 mm N/A 79-5/8 in2022 mm
Jacket Diameter B N/A 28-1/4 in724 mm
Vent Diameter C N/A 8 in203 mm
Floor to Hot Water Outlet D N/A 54-1/8 in1375 mm N/A 54-1/8 in1375 mm N/A 64-1/4 in1632 mm N/A 64-1/4 in1632 mm
Floor to Cold Water Inlet E N/A 28-7/8 in733 mm
Floor to Gas Connection F N/A 10-1/2 in267 mm
Floor to Vent Height G N/A 68-7/8 in1749 mm N/A 68-7/8 in1749 mm N/A 79-1/8 in2010 mm N/A 79-1/8 in2010 mm
Gas Connection1 N/A 1 in25 mm
Relief Valve Opening N/A 1 in25 mm
Standard Approximate Shipping Weight N/A 720 lb326 kg N/A 720 lb326 kg N/A 800 lb363 kg N/A 800 lb363 kg
ASME Approximate Shipping Weight N/A 775 lb352 kg N/A 775 lb352 kg N/A 880 lb399 kg N/A 880 lb399 kg
Style N/A Electronic Ignition Induced Draft
Size N/A C
Test Pressure N/A 300 psi2068 kPa
Working Pressure N/A 150 psi1034 kPa
Industry Standards N/A ANSI ASHRAE 90.1b (Current Standards) ASME Certified C.E.C. Listed CSA® Certified NSF N/A ANSI ASHRAE 90.1b (Current Standards) ASME Certified C.E.C. Listed CSA® Certified N/A ANSI ASHRAE 90.1b (Current Standards) ASME Certified C.E.C. Listed CSA® Certified N/A ANSI ASHRAE 90.1b (Current Standards) ASME Certified C.E.C. Listed CSA® Certified
Features N/A
  • ICON HD™ - Intelligent proven design combines temperature control, diagnostic codes, and system ignition functions into a single control board with a digital LCD display. Control panel cover tilts down for ease of wiring and service.
  • Operation Mode - Two different digitally displayed operation modes have the capability of adjusting the temperature setting up to 180 ºF (82 ºC), and adjusting the degree setting (ºF to ºC, or ºC to ºF).
  • Service Mode - Eight different digitally displayed service modes can be easily cycled through by pressing the select button. There is the capability of adjusting the temperature setting up to 180 ºF (82 ºC), adjusting the degree setting (ºF to ºC, or ºC to ºF), locking the maximum temperature setting that can be adjusted in operation mode, displaying the average water temperature (if water heater has two sensors), displaying the upper temperature sensor, displaying the lower temperature sensor, displaying the flame current of the pilot flame, and displaying diagnostic codes.
  • Electronic Ignition - High voltage, low current electricity is sent to the pilot electrode initiating a spark to ignite the pilot gas. This results in savings of pilot gas during stand-by periods because the pilot flame only operates when there's a call for heat.
  • Factory Installed Hydrojet® Sediment Reduction System - Cold water inlet sediment reducing device helps prevent sediment build up in the tank.
  • Vitraglas® Lining - Bradford White tanks are lined with an exclusively engineered enamel formula that provides superior tank protection from the highly corrosive effects of hot water. This formula (Vitraglas®) is fused to the steel surface by firing at a temperature of over 1600 ºF.
  • 2" Non-CFC Foam Insulation - Covers the sides and top of tank, reducing the amount of heat loss. This results in less energy consumption, improved operation efficiencies and jacket rigidity.
  • Potable Water Connections 1 1/2" NPT factory installed true dielectric fittings extend water heater life and eases installation.
  • Protective Magnesium Anode Rods - Provide added protection against corrosion for long trouble-free service.
  • Hand Hole Cleanout - Allows inspection of tank interior and removal of sediment deposits.
  • E.C.O. - An automatic reset Energy Cut Off (E.C.O) shuts off all gas in event of an overheat condition. This automatically resets when operation conditions are back to normal.
  • Sanitizing Capability - Temperature setting up to 180 ºF (82 ºC).
  • NSF Construction Available.
  • ASME Code Available.
  • T&P Relief Valve - Installed.
  • Brass Drain Valve - Tamper proof.
  • Design Certified by CSA® International (Formerly AGA and CGA).
General Information N/A All gas water heaters are certified at 300 psi test pressure (2068 kPa) and 150 psi working pressure (1034 kPa). All models are design certified by CSA® International (formerly AGA/CGA), ANSI standard Z-21.10.3, for up to 180 ºF (82 ºC) application as an Automatic Storage Heater, and an Automatic Circulating Tank Heater. As an Automatic Storage Heater, all models are complete, self-contained water heating systems. It needs no separate storage tank, pump, wiring or elaborate piping network. When equipped with a mixing valve, it will supply 180 ºF (82 ºC) sanitizing and lower temperature general purpose hot water simultaneously. These models can be used either as a single unit or in multiples connected in series or parallel (recommended).

Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement.
Warranty N/A
  • 3-Year Limited Tank Warranty / 1-Year Limited Warranty on Component Parts.
Note N/A ASME Construction Available.

Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed 80% Recovery Efficiency.
  • 1 LP Gas Connection 3/4 in. (76 mm).