Items |
75T-80B-3N Light Duty Commercial Atmospheric Vent High Input Energy Saver Gas Water Heaters |
75T-80S-3X Light Duty Commercial Atmospheric Vent High Input Energy Saver Gas Water Heaters |
75T-80B-5N Light Duty Commercial Atmospheric Vent High Input Energy Saver Gas Water Heaters |
75T-80S-5X Light Duty Commercial Atmospheric Vent High Input Energy Saver Gas Water Heaters |
100T-88B-3N Light Duty Commercial Atmospheric Vent High Input Energy Saver Gas Water Heaters |
|||||
Manufacturer | N/A Bradford White® | |||||||||
Capacity | N/A 75 U.S. gal63 Imp. gal284 L | N/A 75 U.S. gal63 Imp. gal284 L | N/A 75 U.S. gal63 Imp. gal284 L | N/A 75 U.S. gal63 Imp. gal284 L | N/A 100 U.S. gal83 Imp. gal379 L | |||||
Input Power | N/A 76000 BTU/hr22.3 kW | N/A 76000 BTU/hr22.3 kW | N/A 76000 BTU/hr22.3 kW | N/A 76000 BTU/hr22.3 kW | N/A 85000 BTU/hr24.9 kW | |||||
Recovery at 100 ºF Temperature Rise | N/A 74 U.S. gal/h62 Imp. gal/h | N/A 74 U.S. gal/h62 Imp. gal/h | N/A 74 U.S. gal/h62 Imp. gal/h | N/A 74 U.S. gal/h62 Imp. gal/h | N/A 82 U.S. gal/h69 Imp. gal/h | |||||
Recovery at 56 ºC Temperature Rise | N/A 280 L/h | N/A 280 L/h | N/A 280 L/h | N/A 280 L/h | N/A 310 L/h | |||||
Type | N/A Natural Gas | N/A Liquid Propane Gas | N/A Natural Gas | N/A Liquid Propane Gas | N/A Natural Gas | |||||
Schematic |
N/A
Schematic Drawing for Light Duty Commercial Atmospheric Vent High Input Energy Saver Gas Water Heaters (75T-80 Model) |
N/A
Schematic Drawing for Light Duty Commercial Atmospheric Vent High Input Energy Saver Gas Water Heaters (75T-80 Model) |
N/A
Schematic Drawing for Light Duty Commercial Atmospheric Vent High Input Energy Saver Gas Water Heaters (75T-80 Model) |
N/A
Schematic Drawing for Light Duty Commercial Atmospheric Vent High Input Energy Saver Gas Water Heaters (75T-80 Model) |
N/A
Schematic Drawing for Light Duty Commercial Atmospheric Vent High Input Energy Saver Gas Water Heaters (100T-88 Model) |
|||||
Floor to Flue Connection A | N/A 62-3/8 in1575 mm | N/A 62-3/8 in1575 mm | N/A 62-3/8 in1575 mm | N/A 62-3/8 in1575 mm | N/A 69-1/32 in1745 mm | |||||
Jacket Diameter B | N/A 26 in660 mm | N/A 26 in660 mm | N/A 26 in660 mm | N/A 26 in660 mm | N/A 28-1/4 in718 mm | |||||
Vent Size C | N/A 4 in102 mm | |||||||||
Floor to T and P Connection D | N/A 51-3/4 in1321 mm | N/A 51-3/4 in1321 mm | N/A 51-3/4 in1321 mm | N/A 51-3/4 in1321 mm | N/A 59-3/8 in1507 mm | |||||
Floor to Gas Connection E | N/A 15 in381 mm | N/A 15 in381 mm | N/A 15 in381 mm | N/A 15 in381 mm | N/A 15-17/32 in397 mm | |||||
Floor to Space Heating Inlet F | N/A 16-5/8 in432 mm | N/A 16-5/8 in432 mm | N/A 16-5/8 in432 mm | N/A 16-5/8 in432 mm | N/A 17-3/4 in448 mm | |||||
Floor to Space Heating Outlet G | N/A 51-3/4 in1321 mm | N/A 51-3/4 in1321 mm | N/A 51-3/4 in1321 mm | N/A 51-3/4 in1321 mm | N/A 50-23/32 in1286 mm | |||||
Floor to Water Connection H | N/A 60-5/8 in1549 mm | N/A 60-5/8 in1549 mm | N/A 60-5/8 in1549 mm | N/A 60-5/8 in1549 mm | N/A 67-23/32 in1651 mm | |||||
Depth K | N/A 28-3/8 in718 mm | N/A 28-3/8 in718 mm | N/A 28-3/8 in718 mm | N/A 28-3/8 in718 mm | N/A 32-1/4 in797 mm | |||||
Approximate Shipping Weight | N/A 247 lb112 kg | N/A 247 lb112 kg | N/A 247 lb112 kg | N/A 247 lb112 kg | N/A 420 lb191 kg | |||||
Test Pressure | N/A 300 psi2068 kPa | |||||||||
Working Pressure | N/A 150 psi1034 kPa | |||||||||
Style | N/A Light-Duty High Input Atmosphere Vent | |||||||||
Size | N/A C | |||||||||
Industry Standards | N/A ANSI Standards Z-21.10.3 ASHRAE 90.1b (Current Standards) C.E.C. Listed CSA® Certified | |||||||||
Features |
N/A
|
|||||||||
General Information |
N/A
All gas water heaters are certified at 300 psi test pressure (2068 kPa) and 150 psi working pressure (1034 kPa). The 75 gallon model (284 liters) has 1" (25 mm) water connections on 11" (279 mm) centers and 100 gallon model (379 liters) has 1-1/4" (32 mm) water connections on 16" (406 mm) centers. All gas connections are 1/2" (13 mm). All models design certified by CSA International (formerly AGA/CGA), ANSI standard Z-21.10.3 and peak performance rated. Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement. Suitable for Water (Potable) Heating and Space Heating. Toxic chemicals, such as those used for boiler treatment, shall NEVER be introduced into this system. This unit may NEVER be connected to any existing heating system or component(s) previously used with a non-potable water heating appliance. |
|||||||||
Warranty |
N/A
|
N/A
|
N/A
|
N/A
|
N/A
|
|||||
Note |
N/A
Meet or exceed ASHRAE 90.1b (Current standard) C.E.C. Listed 80% Thermal Efficiency. 75T has optional hand hole cleanout. Meets NAECA Requirements. |
N/A
Meet or exceed ASHRAE 90.1b (Current standard) C.E.C. Listed 80% Thermal Efficiency. Propane models feature a Titanium Stainless Steel propane burner. 75T has optional hand hole cleanout. Meets NAECA Requirements. |
N/A
Meet or exceed ASHRAE 90.1b (Current standard) C.E.C. Listed 80% Thermal Efficiency. 75T has optional hand hole cleanout. Meets NAECA Requirements. |
N/A
Meet or exceed ASHRAE 90.1b (Current standard) C.E.C. Listed 80% Thermal Efficiency. Propane models feature a Titanium Stainless Steel propane burner. 75T has optional hand hole cleanout. Meets NAECA Requirements. |
N/A
Meet or exceed ASHRAE 90.1b (Current standard) C.E.C. Listed 80% Thermal Efficiency. 100T models feature hand hole cleanout. Meets NAECA Requirements. |
|||||
|