Print Back
High Efficiency Series Commercial Gas Water Heaters
Unit of Measure
Items High Efficiency Series Commercial Gas Water Heaters
HE-70-125
High Efficiency Series Commercial Gas Water Heaters
High Efficiency Series Commercial Gas Water Heaters
HE-70-125-LP
High Efficiency Series Commercial Gas Water Heaters
High Efficiency Series Commercial Gas Water Heaters
HE-100-150
High Efficiency Series Commercial Gas Water Heaters
High Efficiency Series Commercial Gas Water Heaters
HE-100-199
High Efficiency Series Commercial Gas Water Heaters
High Efficiency Series Commercial Gas Water Heaters
HE-100-250
High Efficiency Series Commercial Gas Water Heaters
Manufacturer N/A American Standard®
Capacity N/A 70 U.S. gal N/A 70 U.S. gal N/A 100 U.S. gal N/A 100 U.S. gal N/A 100 U.S. gal
Input Power N/A 125000 BTU N/A 125000 BTU N/A 150000 BTU N/A 199000 BTU N/A 250000 BTU
First Hour Delivery at 100 ºF Temperature Rise N/A 195 N/A 195 N/A 245 N/A 305 N/A 358
Thermal Efficiency N/A 96.4 % N/A 96.4 % N/A 98 % N/A 97.5 % N/A 95.3 %
Schematic N/A
Schematic Drawing for High Efficiency Series Commercial Gas Water Heaters
Floor to Top of Heater A N/A 69 in N/A 69 in N/A 76-7/8 in N/A 76-7/8 in N/A 76-7/8 in
Floor to Cold Water Inlet B N/A 7-1/4 in
Floor to Hot Water Outlet C N/A 63-3/4 in N/A 63-3/4 in N/A 71-1/2 in N/A 71-1/2 in N/A 71-1/2 in
Floor to Air Intake D N/A 60-1/8 in N/A 60-1/8 in N/A 68-1/8 in N/A 68-1/8 in N/A 68-1/8 in
Floor to Exhaust E N/A 9-1/4 in
Floor to Top T and P N/A 51 in N/A 51 in N/A 58 in N/A 58 in N/A 58 in
Heater Diameter G N/A 26-3/8 in N/A 26-3/8 in N/A 28-3/8 in N/A 28-3/8 in N/A 28-3/8 in
Floor to Drain H N/A 5-1/2 in
Floor to Gas Inlet J N/A 62-1/4 in N/A 62-1/4 in N/A 70-1/4 in N/A 70-1/4 in N/A 70-1/4 in
Water Connection (In) N/A 1-1/2 in
Water Connection (Out) N/A 1-1/2 in
Gas Connection N/A 1/2 in
T and P Connection N/A 3/4 in N/A 3/4 in N/A 3/4 in N/A 3/4 in N/A 1 in
Approximate Shipping Weight N/A 290 lb N/A 290 lb N/A 490 lb N/A 490 lb N/A 490 lb
Recovery at 30 ºF Temperature Rise N/A 487 gal/h N/A 487 gal/h N/A 594 gal/h N/A 784 gal/h N/A 963 gal/h
Recovery at 40 ºF Temperature Rise N/A 365 gal/h N/A 365 gal/h N/A 446 gal/h N/A 588 gal/h N/A 722 gal/h
Recovery at 50 ºF Temperature Rise N/A 292 gal/h N/A 292 gal/h N/A 356 gal/h N/A 470 gal/h N/A 578 gal/h
Recovery at 60 ºF Temperature Rise N/A 365 gal/h N/A 365 gal/h N/A 297 gal/h N/A 392 gal/h N/A 418 gal/h
Recovery at 70 ºF Temperature Rise N/A 209 gal/h N/A 209 gal/h N/A 255 gal/h N/A 336 gal/h N/A 413 gal/h
Recovery at 80 ºF Temperature Rise N/A 183 gal/h N/A 183 gal/h N/A 223 gal/h N/A 294 gal/h N/A 361 gal/h
Recovery at 90 ºF Temperature Rise N/A 162 gal/h N/A 162 gal/h N/A 198 gal/h N/A 261 gal/h N/A 321 gal/h
Recovery at 100 ºF Temperature Rise N/A 146 gal/h N/A 146 gal/h N/A 175 gal/h N/A 235 gal/h N/A 288 gal/h
Recovery at 110 ºF Temperature Rise N/A 133 gal/h N/A 133 gal/h N/A 162 gal/h N/A 214 gal/h N/A 263 gal/h
Recovery at 120 ºF Temperature Rise N/A 122 gal/h N/A 122 gal/h N/A 149 gal/h N/A 196 gal/h N/A 241 gal/h
Recovery at 130 ºF Temperature Rise N/A 112 gal/h N/A 112 gal/h N/A 137 gal/h N/A 181 gal/h N/A 222 gal/h
Recovery at 140 ºF Temperature Rise N/A 104 gal/h N/A 104 gal/h N/A 127 gal/h N/A 168 gal/h N/A 206 gal/h
Sides Installation Clearances N/A 0 in
Front Installation Clearances N/A 0 in
Rear Installation Clearances N/A 0 in
Top Installation Clearances N/A 0 in
To Combustible Installation Clearances N/A 0 in
Maximum Equivalent Vent Length using 2" Pipe PVC, ABS, and CPVC N/A 65 ft
Maximum Equivalent Vent Length using 3" Pipe PVC, ABS, and CPVC N/A 135 ft
Maximum Equivalent Vent Length using 4" Pipe PVC, ABS, and CPVC N/A 135 ft
Gas Valve Piping at Inlet Size N/A 1/2 in
Type N/A Natural Gas N/A Liquid Propane Gas N/A Natural Gas N/A Natural Gas N/A Natural Gas
Size N/A C
Industry Standards N/A ANSI Z-21.10.3 - CSA 4.3 ASHRAE Standards 90.1-1999 ETL
Testing and Certifications N/A
  • CSA® Design Certified - In conformance with ANSI Z21.10.3-CSA® 4.3. Meets and exceeds ASHRAE 90.1-1999
  • CEC listed. CSA® certified to meet NSF/ANSI 5 Standards
Features N/A
  • Thermal Efficiency Up to 98% - Exceeds ASHRAE 80% requirement.
  • Flexible Venting - Allows optional vertical or horizontal venting and certified for direct vent sealed combustion applications. Provides 135 equivalent feet for 3" or 4" venting and 65 equivalent feet for 2" venting with PVC, CPVC or ABS vent pipe.
  • Electronic Control of Ignition and Thermostat - provides accurate water temperature settings from 100 ºF to 180 ºF. Display panel indicates operating mode, settings and any failure modes for ease of service.
  • Submerged Combustion Chamber - Minimizes radiant heat loss and improves efficiency.
  • Zero Inch Clearance - To combustibles to provide additional installation flexibility.
  • Inner Tank Glasslined - With Dura-Glas™ and fired at 1600 ºF for optimum protection from the effects of corrosion.
  • Magnesium Anode Rods - To extend tank life.
  • Non-CFC Foam Insulated - To save energy and reduce fuel costs by maximizing heat retention.
  • Full Size Hand-Hole Cleanout - For eased tank inspection and/or removal of sediment deposits.
  • Factory Installed Energy Cut-Off System And Pressure/temperature Valve.
  • Low NOx Burner - Exceeds California SCAQMD, BAAQMD and state of Texas requirements.
  • American Standard® gas water heaters are certified at 300 psi test pressure and for 150 psi working pressure. All tanks are hydrostatically tested at the factory.
Warranty N/A
  • 3-Year Limited Warranty - On Inner Glass-Lined Tank.
  • 1-Year Limited Warranty - On all Other Component Parts.
Note N/A Manufacturer reserves the right to make product changes and/or improvements with or without notice.