Light Duty Commercial Electric Water Heaters
Unit of Measure
Items Light Duty Commercial Electric Water Heaters
LD-CE-30-T-AS-1500W
Light Duty Commercial Electric Water Heaters
Light Duty Commercial Electric Water Heaters
LD-CE-30-T-AS-2000W
Light Duty Commercial Electric Water Heaters
Light Duty Commercial Electric Water Heaters
LD-CE-30-T-AS-2500W
Light Duty Commercial Electric Water Heaters
Light Duty Commercial Electric Water Heaters
LD-CE-30-T-AS-3000W
Light Duty Commercial Electric Water Heaters
Light Duty Commercial Electric Water Heaters
LD-CE-30-T-AS-3500W
Light Duty Commercial Electric Water Heaters
Manufacturer N/A American Standard®
Capacity N/A 30 gal
Schematic N/A
Schematic Drawing for Light-Duty Commercial Electric Water Heaters
Jacket Diameter A N/A 18-1/4 in
Floor to Water Connection B N/A 48-3/4 in
Floor to Top of Heater C N/A 46 in
Floor to Side T and P D N/A 40-1/4 in
Water Spread E N/A 8 in
Standard Voltage N/A 240 V
Maximum Input Power N/A 12 kW
Standard Shipping Weight N/A 98 lb
Element Power N/A 1500 W N/A 2000 W N/A 2500 W N/A 3000 W N/A 3500 W
Recovery at 40 ºF Temperature Rise N/A N/A N/A N/A 31 gal/h N/A 36 gal/h
Recovery at 50 ºF Temperature Rise N/A N/A N/A N/A 25 gal/h N/A 29 gal/h
Recovery at 60 ºF Temperature Rise N/A N/A N/A N/A 20 gal/h N/A 24 gal/h
Recovery at 70 ºF Temperature Rise N/A N/A N/A N/A 18 gal/h N/A 20 gal/h
Recovery at 80 ºF Temperature Rise N/A N/A N/A N/A 15 gal/h N/A 18 gal/h
Recovery at 90 ºF Temperature Rise N/A N/A N/A N/A 14 gal/h N/A 16 gal/h
Recovery at 100 ºF Temperature Rise N/A N/A N/A N/A 12 gal/h N/A 14 gal/h
Full Load Current Single Phase 120 V N/A 12.5 A N/A 16.7 A N/A 20.8 A N/A 25 A N/A
Full Load Current Single Phase 208 V N/A 7.2 A N/A 9.6 A N/A 12 A N/A 14.4 A N/A 16.8 A
Full Load Current Single Phase 240 V N/A 6.3 A N/A 8.3 A N/A 10.4 A N/A 12.5 A N/A 14.6 A
Full Load Current Single Phase 277 V N/A 5.4 A N/A 7.2 A N/A 9 A N/A 10.8 A N/A 12.6 A
Full Load Current Single Phase 480 V N/A 3.1 A N/A 4.2 A N/A 5.2 A N/A 6.3 A N/A 7.3 A
Full Load Current Three Phase 208 V (All Terminals L1, L2, and L3) N/A N/A N/A N/A 14.4 A N/A
Full Load Current Three Phase 240 V (All Terminals L1, L2, and L3) N/A N/A N/A N/A 12.5 A N/A
Full Load Current Three Phase 480 V (All Terminals L1, L2, and L3) N/A N/A N/A N/A 6.3 A N/A
Full Load Current Three Phase 208 V (Terminal L3) N/A N/A N/A N/A 25 A N/A
Full Load Current Three Phase 240 V (Terminal L3) N/A N/A N/A N/A 21.7 A N/A
Full Load Current Three Phase 480 V (Terminal L3) N/A N/A N/A N/A 10.8 A N/A
Full Load Current Three Phase 208 V (Terminal L1 and L2) N/A N/A N/A N/A 14.4 A N/A
Full Load Current Three Phase 240 V (Terminal L1 and L2) N/A N/A N/A N/A 12.5 A N/A
Full Load Current Three Phase 480 V (Terminal L1 and L2) N/A N/A N/A N/A 6.3 A N/A
Operation Type N/A N/A N/A N/A Interlocking Operation Simultaneous Operation N/A
Voltage N/A 120 V208 V240 V277 V480 V N/A 120 V208 V240 V277 V480 V N/A 120 V208 V240 V277 V480 V N/A 120 V208 V240 V277 V480 V N/A 208 V240 V277 V480 V
Phase N/A Single N/A Single N/A Single N/A Single Three N/A Single
Test Pressure N/A 300 psi
Working Pressure N/A 150 psi
Size N/A C
Type N/A Electric
Model Type N/A Tall
Industry Standards N/A ANSI ASHRAE 90.1b-1992 C.E.C. Listed UL® 174
Features N/A
  • Surface Mount Thermostats - Fully automatic for temperature control.
  • Dual Heating Elements - Screw-in, direct immersion, 4500 watt, 240 volt incoloy heating elements for maximum efficiency. Available in 120, 208, 240, 277, & 480 voltages, single- or three-phase. Wattages available up to 12 KW.
  • Self-Cleaning - Turbulence inducing cold water inlet-tube engineered to diminish hard water area sediment deposits.
  • Non-CFC Foam Insulated - Full 2" foam insulation saves energy & reduces fuel costs by maximizing heat retention.
  • Heavy Gauge Steel Tank - For extra years of trouble-free service.
  • Glass-Lined Tank - Inner tank glass-lined with Dura-Glas™ & fired at 1600 ºF for optimum protection from the effects of corrosion.
  • Magnesium Anode Rod - To prolong tank life.
  • Electric Junction Box - For 1/2" or 3/4" conduit.
  • Factory Installed Dielectric Hot & Cold Water Connections - 3 4" NPT water connections to extend tank life & for easier installations.
  • Brass Drain Valve - Durable & to prevent unintentional breakage.
  • Factory Installed Heat Traps - Reduces standby heat loss in water piping.
  • Temperature & Pressure Relief Valve - Factory provided T & P Valve can be relocated from side to optional top opening.
  • Factory Installed Energy Cut-Off System - Manual reset energy cut-off prevents overheating.
Testing and Certifications N/A
  • Certified By Underwriters Laboratories - Listed to UL 174, meets or exceeds efficiency requirements of the Department of Energy, ASHRAE Standard 90.1 b-1992. National Appliance Energy Conservation Act, ANSI requirements, is CEC listed & tested in accordance with D.O.E. test procedures & all state energy efficiency standards
  • American Standard® Commercial Electric Water Heaters - are certified at 300 PSI test pressure & 150 PSI working pressure, & all tanks are 100% hydrostatically tested at the factory
  • UL Listed
Warranty N/A
  • 3-Year Limited Warranty - On Inner Glass-Lined Tank.
  • 1-Year Limited Warranty - On all Other Component Parts.
Note N/A These water heaters meet or exceed ASHRAE 90.1b-1992 standards and are listed with the California energy commission.