Catalog
The 50-gallon, 76,000 BTU Force™ 90 light-duty commercial gas water heater is equipped with a fully submerged, spiral-shaped condensing heat exchanger. This design provides a much greater heat transfer surface than a standard straight flue tube, resulting in 90% thermal efficiency and higher hot water output than comparable 80% efficient water heaters. With 22" diameter, the 50-gallon Force™ 90 can be installed in less space than a 75-gallon unit and delivers greater recovery and lower operating costs.
Unit of Measure
Specifications
|
Dimensions
|
Maximum Recovery
|
Electrical Characteristics
|
Features
|
Testing and Certifications
|
Warranty
|
Note
Specifications
Manufacturer |
N/A State® |
Top/Side Inlet (NPT) |
N/A 3/4 in |
Top/Side Outlet (NPT) |
N/A 3/4 in |
Gas Inlet (NPT) |
N/A 1/2 in |
Approximate Capacity |
N/A 50 U.S. gal189 L |
Manifold Pressure |
N/A 4 inWc0.99 kPa |
Input Power |
N/A 76000 BTU/hr22.25 kW·h |
Maximum Temperature Setting |
N/A 180 ºF |
Type |
N/A Natural Gas |
Style |
N/A Force™ 90 |
Size |
N/A C |
Maximum Hydrostatic Working Pressure (Compliance) |
N/A 150 psi |
Industry Standards |
N/A ANSI Z-21.10.3 - CSA 4.3 ASHRAE/IESNA 90.1 UL® Listed |
Dimensions
Maximum Recovery
Recovery at 30 ºF Temperature Rise |
N/A 275 gal/h |
Recovery at 17 ºC Temperature Rise |
N/A 1041 L/h |
Recovery at 40 ºF Temperature Rise |
N/A 206 gal/h |
Recovery at 22 ºC Temperature Rise |
N/A 780 L/h |
Recovery at 50 ºF Temperature Rise |
N/A 165 gal/h |
Recovery at 28 ºC Temperature Rise |
N/A 625 L/h |
Recovery at 60 ºF Temperature Rise |
N/A 138 gal/h |
Recovery at 33 ºC Temperature Rise |
N/A 522 L/h |
Recovery at 70 ºF Temperature Rise |
N/A 118 gal/h |
Recovery at 39 ºC Temperature Rise |
N/A 447 L/h |
Recovery at 80 ºF Temperature Rise |
N/A 104 gal/h |
Recovery at 44 ºC Temperature Rise |
N/A 394 L/h |
Recovery at 90 ºF Temperature Rise |
N/A 92 gal/h |
Recovery at 50 ºC Temperature Rise |
N/A 348 L/h |
Recovery at 100 ºF Temperature Rise |
N/A 83 gal/h |
Recovery at 56 ºC Temperature Rise |
N/A 314 L/h |
Recovery at 110 ºF Temperature Rise |
N/A 75 gal/h |
Recovery at 61 ºC Temperature Rise |
N/A 284 L/h |
Recovery at 120 ºF Temperature Rise |
N/A 69 gal/h |
Recovery at 67 ºC Temperature Rise |
N/A 261 L/h |
Recovery at 130 ºF Temperature Rise |
N/A 64 gal/h |
Recovery at 72 ºC Temperature Rise |
N/A 242 L/h |
Recovery at 140 ºF Temperature Rise |
N/A 59 gal/h |
Recovery at 78 ºC Temperature Rise |
N/A 223 L/h |
Features
Features |
N/A
Power Vent Design for Installation Versatility
|
Testing and Certifications
Testing and Certifications |
N/A
CSA® Certified and ASME Rated T&P Relief Valve Maximum Hydrostatic Working Pressure: 150 psi Compliance
|
Note
Note |
N/A
All models - Maximum Supply Pressure: 14 inches W.C. (3.48 kPa) Minimum Supply Pressure Natural Gas: 5.0 inches W.C. (1.24 kPa) Minimum Pressure must be maintained under both load and no load (Static and dynamic) conditions. Recovery Capacities - U.S. Gallons/Hr. and Liters/Hr. at Temperature Rise Indicated Recovery capacity based on 90% thermal efficiency Install in accordance with local codes |