Catalog
Unit of Measure

Specifications

Manufacturer

N/A American Standard®

Capacity

N/A 30 gal

Standard Voltage

N/A 240 V

Maximum Input Power

N/A 12 kW

Standard Shipping Weight

N/A 98 lb

Element Power

N/A 11000 W

Voltage

N/A 240 V277 V480 V

Phase

N/A Single

Test Pressure

N/A 300 psi

Working Pressure

N/A 150 psi

Size

N/A C

Type

N/A Electric

Model Type

N/A Tall

Industry Standards

N/A ANSI ASHRAE 90.1b-1992 C.E.C. Listed UL® 174

Dimensions

Schematic

N/A
Schematic Drawing for Light-Duty Commercial Electric Water Heaters

Jacket Diameter A

N/A 18-1/4 in

Floor to Water Connection B

N/A 48-3/4 in

Floor to Top of Heater C

N/A 46 in

Floor to Side T and P D

N/A 40-1/4 in

Water Spread E

N/A 8 in

Maximum Recovery

Recovery at 40 ºF Temperature Rise

N/A 113 gal/h

Recovery at 50 ºF Temperature Rise

N/A 90 gal/h

Recovery at 60 ºF Temperature Rise

N/A 75 gal/h

Recovery at 70 ºF Temperature Rise

N/A 64 gal/h

Recovery at 80 ºF Temperature Rise

N/A 56 gal/h

Recovery at 90 ºF Temperature Rise

N/A 50 gal/h

Recovery at 100 ºF Temperature Rise

N/A 45 gal/h

Electrical Characteristics

Full Load Current Single Phase 240 V

N/A 45.8 A

Full Load Current Single Phase 277 V

N/A 39.7 A

Full Load Current Single Phase 480 V

N/A 22.9 A

Features

Features

N/A
  • Surface Mount Thermostats - Fully automatic for temperature control.
  • Dual Heating Elements - Screw-in, direct immersion, 4500 watt, 240 volt incoloy heating elements for maximum efficiency. Available in 120, 208, 240, 277, & 480 voltages, single- or three-phase. Wattages available up to 12 KW.
  • Self-Cleaning - Turbulence inducing cold water inlet-tube engineered to diminish hard water area sediment deposits.
  • Non-CFC Foam Insulated - Full 2" foam insulation saves energy & reduces fuel costs by maximizing heat retention.
  • Heavy Gauge Steel Tank - For extra years of trouble-free service.
  • Glass-Lined Tank - Inner tank glass-lined with Dura-Glas™ & fired at 1600 ºF for optimum protection from the effects of corrosion.
  • Magnesium Anode Rod - To prolong tank life.
  • Electric Junction Box - For 1/2" or 3/4" conduit.
  • Factory Installed Dielectric Hot & Cold Water Connections - 3 4" NPT water connections to extend tank life & for easier installations.
  • Brass Drain Valve - Durable & to prevent unintentional breakage.
  • Factory Installed Heat Traps - Reduces standby heat loss in water piping.
  • Temperature & Pressure Relief Valve - Factory provided T & P Valve can be relocated from side to optional top opening.
  • Factory Installed Energy Cut-Off System - Manual reset energy cut-off prevents overheating.

Testing and Certifications

Testing and Certifications

N/A
  • Certified By Underwriters Laboratories - Listed to UL 174, meets or exceeds efficiency requirements of the Department of Energy, ASHRAE Standard 90.1 b-1992. National Appliance Energy Conservation Act, ANSI requirements, is CEC listed & tested in accordance with D.O.E. test procedures & all state energy efficiency standards
  • American Standard® Commercial Electric Water Heaters - are certified at 300 PSI test pressure & 150 PSI working pressure, & all tanks are 100% hydrostatically tested at the factory
  • UL Listed

Warranty

Warranty

N/A
  • 3-Year Limited Warranty - On Inner Glass-Lined Tank.
  • 1-Year Limited Warranty - On all Other Component Parts.

Note

Note

N/A These water heaters meet or exceed ASHRAE 90.1b-1992 standards and are listed with the California energy commission.