Specifications
|
Maximum Recovery (ºF)
|
Maximum Recovery (ºC)
|
Dimensions
|
Features
|
Testing and Certifications
|
Warranty
|
Note
Specifications
Manufacturer |
N/A A. O. Smith® |
Input Power |
N/A 80000 BTU/hr23.4 kW |
Approximate Capacity |
N/A 74 U.S. gal280 L |
Type |
N/A Liquid Propane Gas |
Thermal Efficiency |
N/A 80 % |
Pipe Material |
N/A CPVC PVC |
Industry Standards |
N/A ANSI Z-21.10.3 - CSA 4.3 ASHRAE/IESNA 90.1-2004 CSA® Certified UL® Listed |
Maximum Recovery (ºF)
Recovery at 30 ºF Temperature Rise |
N/A 259 gal/h |
Recovery at 40 ºF Temperature Rise |
N/A 194 gal/h |
Recovery at 50 ºF Temperature Rise |
N/A 155 gal/h |
Recovery at 60 ºF Temperature Rise |
N/A 129 gal/h |
Recovery at 70 ºF Temperature Rise |
N/A 111 gal/h |
Recovery at 80 ºF Temperature Rise |
N/A 97 gal/h |
Recovery at 90 ºF Temperature Rise |
N/A 86 gal/h |
Recovery at 100 ºF Temperature Rise |
N/A 78 gal/h |
Recovery at 110 ºF Temperature Rise |
N/A 71 gal/h |
Recovery at 120 ºF Temperature Rise |
N/A 65 gal/h |
Recovery at 130 ºF Temperature Rise |
N/A 60 gal/h |
Recovery at 140 ºF Temperature Rise |
N/A 55 gal/h |
Maximum Recovery (ºC)
Recovery at 17 ºC Temperature Rise |
N/A 979 L/h |
Recovery at 22 ºC Temperature Rise |
N/A 734 L/h |
Recovery at 28 ºC Temperature Rise |
N/A 587 L/h |
Recovery at 33 ºC Temperature Rise |
N/A 489 L/h |
Recovery at 39 ºC Temperature Rise |
N/A 419 L/h |
Recovery at 44 ºC Temperature Rise |
N/A 367 L/h |
Recovery at 50 ºC Temperature Rise |
N/A 326 L/h |
Recovery at 56 ºC Temperature Rise |
N/A 294 L/h |
Recovery at 61 ºC Temperature Rise |
N/A 267 L/h |
Recovery at 67 ºC Temperature Rise |
N/A 245 L/h |
Recovery at 72 ºC Temperature Rise |
N/A 226 L/h |
Recovery at 78 ºC Temperature Rise |
N/A 210 L/h |
Dimensions
Features
Features |
N/A
CFC-Free Foam Insulation - Minimizes radiant heat Loss. Dip Tube - Carries inlet water deep into tank. Hot Surface Ignition - Has a solid state ignition surface that does not flutter or blow out. Provides increased reliability and efficiency over spark ignition systems. Eliminates the pilot and saves energy. Intelli-Vent Control - Provides temperature control and LED diagnostics. Glass lined Tank - Glass specifically developed by A. O. Smith® for water heaters is permanently fused to steel at 1,600° F, providing years of corrosion protection and dependable use. Anode - Tank-mounted, screw-in replaceable anode for longer tank life. High Input - 80,000 BTU input assures plenty of hot water is available by providing faster recovery rates and higher first hour draws. Burner - High input, multiport burner for improved combustion efficiency and low NOx. Turbo Shot™ Combustion System - Air is precisely drawn through the combustion control port and exhausted through plastic pipe. Controlling the airflow through the heater enhances and regulates the combustion process. In standby mode, the combustion control port restricts air circulation through the heater. Powered Venting - Provides more venting flexibility and savings. A new quiet blower allows exhaust venting through the roof or sidewall with plastic pipe such as PVC, CPVC, and ABS. Allowable vent lengths of up to 100 equivalent feet make installation easy in any situation. BTF-80 is a Category 3 (positive pressure non-condensing) appliance. Built-In Condensate Fitting - A condensate management coupling that attaches vent pipe to the blower and drain hose are included. Installed Temperature & Pressure Relief Valve - Factory installed and matched to the heater. (Specify if your local code requires a special T & P). |