Catalog
Designed for use as a recovery heater having its own storage tank or booster for supplying sanitizing rinse water for dishwashing.
Unit of Measure
Specifications
|
Electrical Characteristics
|
Dimensions
|
Maximum Recovery (ºF)
|
Maximum Recovery (ºC)
|
Testing and Certifications
|
Options
|
Warranty
|
Note
Specifications
Manufacturer |
N/A A. O. Smith® |
Input Power |
N/A 40.5 kW138226 BTU/hr |
Number of Elements |
N/A 9 |
Element Power |
N/A 4500 W |
Tank Capacity |
N/A 80 gal300 L |
Equipment Grade |
N/A Commercial |
Inlet/Outlet (NPT) |
N/A 1-1/4 in3.2 cm |
Approximate Shipping Weight |
N/A 280 lb127 kg |
Heating Source |
N/A Electric |
Industry Standards |
N/A ASHRAE/IESNA 90.1 ASME Certified |
Electrical Characteristics
Full Load Current Single Phase 208 V |
N/A 194.7 A |
Full Load Current Single Phase 240 V |
N/A 168.8 A |
Full Load Current Single Phase 277 V |
N/A 146.2 A |
Full Load Current Single Phase 480 V |
N/A 84.4 A |
Full Load Current Three Phase 208 V |
N/A 112.4 A |
Full Load Current Three Phase 240 V |
N/A 97.4 A |
Full Load Current Three Phase 480 V |
N/A 48.7 A |
Standard Voltage |
N/A 208 V240 V480 V |
Phase |
N/A Single Three |
Maximum Recovery (ºF)
Recovery at 30 ºF Temperature Rise |
N/A 554 gal/h |
Recovery at 40 ºF Temperature Rise |
N/A 418 gal/h |
Recovery at 50 ºF Temperature Rise |
N/A 332 gal/h |
Recovery at 60 ºF Temperature Rise |
N/A 277 gal/h |
Recovery at 70 ºF Temperature Rise |
N/A 237 gal/h |
Recovery at 80 ºF Temperature Rise |
N/A 208 gal/h |
Recovery at 90 ºF Temperature Rise |
N/A 185 gal/h |
Recovery at 100 ºF Temperature Rise |
N/A 166 gal/h |
Recovery at 110 ºF Temperature Rise |
N/A 151 gal/h |
Recovery at 120 ºF Temperature Rise |
N/A 138 gal/h |
Recovery at 130 ºF Temperature Rise |
N/A 128 gal/h |
Recovery at 140 ºF Temperature Rise |
N/A 119 gal/h |
Maximum Recovery (ºC)
Recovery at 17 ºC Temperature Rise |
N/A 2094 L/h |
Recovery at 22 ºC Temperature Rise |
N/A 1570 L/h |
Recovery at 28 ºC Temperature Rise |
N/A 1256 L/h |
Recovery at 33 ºC Temperature Rise |
N/A 1047 L/h |
Recovery at 39 ºC Temperature Rise |
N/A 897 L/h |
Recovery at 45 ºC Temperature Rise |
N/A 785 L/h |
Recovery at 50 ºC Temperature Rise |
N/A 698 L/h |
Recovery at 56 ºC Temperature Rise |
N/A 628 L/h |
Recovery at 61 ºC Temperature Rise |
N/A 634 L/h |
Recovery at 67 ºC Temperature Rise |
N/A 582 L/h |
Recovery at 72 ºC Temperature Rise |
N/A 537 L/h |
Recovery at 78 ºC Temperature Rise |
N/A 498 L/h |
Testing and Certifications
Testing and Certifications |
N/A
Meets the thermal efficiency and or standby loss requirements of the U.S. Department of Energy and current edition of ASHRAE/ISENA 90.1. iCOMM™ Compatible. |