Catalog
Designed for use as a recovery heater having its own storage tank or booster for supplying sanitizing rinse water for dishwashing.
Unit of Measure
Specifications
|
Electrical Characteristics
|
Dimensions
|
Maximum Recovery (ºF)
|
Maximum Recovery (ºC)
|
Testing and Certifications
|
Options
|
Warranty
Specifications
Manufacturer |
N/A A. O. Smith® |
Input Power |
N/A 54 kW184302 BTU/hr |
Number of Elements |
N/A 9 |
Element Power |
N/A 6000 W |
Tank Capacity |
N/A 50 gal189 L |
Equipment Grade |
N/A Commercial |
Inlet/Outlet (NPT) |
N/A 1-1/4 in3.2 cm |
Approximate Shipping Weight |
N/A 265 lb120 kg |
Heating Source |
N/A Electric |
Industry Standards |
N/A ASHRAE/IESNA 90.1 ASME Certified |
Electrical Characteristics
Full Load Current Single Phase 240 V |
N/A 225 A |
Full Load Current Single Phase 277 V |
N/A 194.9 A |
Full Load Current Single Phase 480 V |
N/A 112.5 A |
Full Load Current Three Phase 208 V |
N/A 149.9 A |
Full Load Current Three Phase 240 V |
N/A 129.9 A |
Full Load Current Three Phase 480 V |
N/A 65.0 A |
Standard Voltage |
N/A 208 V240 V480 V |
Phase |
N/A Single Three |
Maximum Recovery (ºF)
Recovery at 30 ºF Temperature Rise |
N/A 738 gal/h |
Recovery at 40 ºF Temperature Rise |
N/A 554 gal/h |
Recovery at 50 ºF Temperature Rise |
N/A 443 gal/h |
Recovery at 60 ºF Temperature Rise |
N/A 359 gal/h |
Recovery at 70 ºF Temperature Rise |
N/A 316 gal/h |
Recovery at 80 ºF Temperature Rise |
N/A 277 gal/h |
Recovery at 90 ºF Temperature Rise |
N/A 246 gal/h |
Recovery at 100 ºF Temperature Rise |
N/A 221 gal/h |
Recovery at 110 ºF Temperature Rise |
N/A 201 gal/h |
Recovery at 120 ºF Temperature Rise |
N/A 185 gal/h |
Recovery at 130 ºF Temperature Rise |
N/A 170 gal/h |
Recovery at 140 ºF Temperature Rise |
N/A 158 gal/h |
Maximum Recovery (ºC)
Recovery at 17 ºC Temperature Rise |
N/A 2791 L/h |
Recovery at 22 ºC Temperature Rise |
N/A 2094 L/h |
Recovery at 28 ºC Temperature Rise |
N/A 1675 L/h |
Recovery at 33 ºC Temperature Rise |
N/A 1396 L/h |
Recovery at 39 ºC Temperature Rise |
N/A 1196 L/h |
Recovery at 45 ºC Temperature Rise |
N/A 1047 L/h |
Recovery at 50 ºC Temperature Rise |
N/A 930 L/h |
Recovery at 56 ºC Temperature Rise |
N/A 837 L/h |
Recovery at 61 ºC Temperature Rise |
N/A 761 L/h |
Recovery at 67 ºC Temperature Rise |
N/A 696 L/h |
Recovery at 72 ºC Temperature Rise |
N/A 644 L/h |
Recovery at 78 ºC Temperature Rise |
N/A 598 L/h |
Testing and Certifications
Testing and Certifications |
N/A
Meets the thermal efficiency and or standby loss requirements of the U.S. Department of Energy and current edition of ASHRAE/ISENA 90.1. iCOMM™ Compatible. |