Catalog
Titan™ Commercial Gas Water Heaters
State® NON NOx Commercial Water Heaters
Unit of Measure
Items |
/Asset/a1307.jpg GPG 81 140NE Titan™ Commercial Gas Water Heaters |
/Asset/a1307.jpg GPG 81 140NEA Titan™ Commercial Gas Water Heaters |
/Asset/a1307.jpg GPG 81 199NE Titan™ Commercial Gas Water Heaters |
/Asset/a1307.jpg GPG 81 199NEA Titan™ Commercial Gas Water Heaters |
/Asset/a1307.jpg GPG 81 270NE Titan™ Commercial Gas Water Heaters |
|||||
Manufacturer | N/A State® | |||||||||
Storage Capacity | N/A 81 U.S. gal | |||||||||
Input Power | N/A 140000 BTU/hr | N/A 140000 BTU/hr | N/A 199000 BTU/hr | N/A 199000 BTU/hr | N/A 270000 BTU/hr | |||||
First Hour Rating | N/A 193 gal | N/A 193 gal | N/A 250 gal | N/A 250 gal | N/A 319 gal | |||||
Recovery at 80 ºF Temperature Rise | N/A 168 gal | N/A 168 gal | N/A 238 gal | N/A 238 gal | N/A 324 gal | |||||
Recovery at 100 ºF Temperature Rise | N/A 136 gal | N/A 136 gal | N/A 193 gal | N/A 193 gal | N/A 262 gal | |||||
Recovery at 140 ºF Temperature Rise | N/A 97 gal | N/A 97 gal | N/A 138 gal | N/A 138 gal | N/A 187 gal | |||||
Schematic |
N/A
Schematic Drawing for Titan™ Commercial Gas Water Heaters |
|||||||||
Dimension A | N/A 74-3/4 in | |||||||||
Dimension B | N/A 65 in | |||||||||
Dimension C | N/A 26-3/4 in | |||||||||
Dimension D | N/A 6 in | |||||||||
Dimension E | N/A 21-3/8 in | |||||||||
Dimension G | N/A 27-3/4 in | |||||||||
Dimension H | N/A 38 in | |||||||||
Dimension J | N/A 85-1/4 in | |||||||||
Gas Connection | N/A 1/2 in | N/A 1/2 in | N/A 1/2 in | N/A 1/2 in | N/A 3/4 in | |||||
Approximate Shipping Weight | N/A 556 lb | N/A 658 lb | N/A 545 lb | N/A 635 lb | N/A 547 lb | |||||
Inlet Water Connection | N/A 1-1/2 in | |||||||||
Outlet Water Connection | N/A 1-1/2 | |||||||||
Thermal Efficiency | N/A 80 % | |||||||||
Working Pressure | N/A 160 psi | |||||||||
Style | N/A State Titan® | |||||||||
Size | N/A C | |||||||||
Type | N/A Natural Gas | |||||||||
Industry Standards | N/A ASHRAE 90.1b-1992 ASME Certified C.E.C. Listed UL® Listed | |||||||||
Features |
N/A
|
|||||||||
Limited Warranty Outline |
N/A
|
|||||||||
Other Features |
N/A
|
|||||||||
Options |
N/A
|
|||||||||
Note |
N/A
CAUTION: Unit must be installed on non-combustible surface. To compensate for the effects of high altitude areas above 2000 feet, recovery capacities should be reduced approximately 4% for every 1000 feet above sea level. Above capacities are based on actual efficiencies obtained in engineering laboratories. |
|||||||||
|