Commercial Flue Damper Electronic Ignition Energy Saver Gas Water Heaters
Bradford White® NON NOx Commercial Water Heaters
Unit of Measure
Items |
/ImgCustom/1002/placeholder_notavailable.gif D-38T-155-3N Commercial Flue Damper Electronic Ignition Energy Saver Gas Water Heaters |
/ImgCustom/1002/placeholder_notavailable.gif D-38T-155-3X Commercial Flue Damper Electronic Ignition Energy Saver Gas Water Heaters |
/ImgCustom/1002/placeholder_notavailable.gif D-38T-155E-3N Commercial Flue Damper Electronic Ignition Energy Saver Gas Water Heaters |
/ImgCustom/1002/placeholder_notavailable.gif D-38T-155E-3X Commercial Flue Damper Electronic Ignition Energy Saver Gas Water Heaters |
/ImgCustom/1002/placeholder_notavailable.gif D-65T-370-3N Commercial Flue Damper Electronic Ignition Energy Saver Gas Water Heaters |
|||||
Manufacturer | N/A Bradford White® | |||||||||
Capacity | N/A 38 U.S. gal31 Imp. gal144 L | N/A 38 U.S. gal31 Imp. gal144 L | N/A 38 U.S. gal31 Imp. gal144 L | N/A 38 U.S. gal31 Imp. gal144 L | N/A 65 U.S. gal54 Imp. gal246 L | |||||
Input Power | N/A 155000 BTU/hr45.4 kW·h | N/A 155000 BTU/hr45.4 kW·h | N/A 155000 BTU/hr45.4 kW·h | N/A 155000 BTU/hr45.4 kW·h | N/A 370000 BTU/hr108.4 kW·h | |||||
First Hour Delivery at 100 ºF Temperature Rise | N/A 177 | N/A 177 | N/A 177 | N/A 177 | N/A 405 | |||||
First Hour Delivery at 56 ºC Temperature Rise | N/A 670 | N/A 670 | N/A 670 | N/A 670 | N/A 1533 | |||||
Recovery at 40 ºF Degree Rise |
N/A 376 gal/h | N/A 376 gal/h | N/A 376 gal/h | N/A 376 gal/h | N/A 897 gal/h | |||||
Recovery at 22 ºC Degree Rise |
N/A 1391 L/h | N/A 1391 L/h | N/A 1391 L/h | N/A 1391 L/h | N/A 3395 L/h | |||||
Recovery at 100 ºF Degree Rise |
N/A 150 gal/h | N/A 150 gal/h | N/A 150 gal/h | N/A 150 gal/h | N/A 359 gal/h | |||||
Recovery at 56 ºC Degree Rise |
N/A 556 L/h | N/A 556 L/h | N/A 556 L/h | N/A 556 L/h | N/A 1359 L/h | |||||
Recovery at 140 ºF Degree Rise |
N/A 107 gal/h | N/A 107 gal/h | N/A 107 gal/h | N/A 107 gal/h | N/A 256 gal/h | |||||
Recovery at 78 ºC Degree Rise |
N/A 397 L/h | N/A 397 L/h | N/A 397 L/h | N/A 397 L/h | N/A 969 L/h | |||||
Schematic |
N/A
Schematic Drawing for Commercial Flue Damper Electronic Ignition Energy Saver Gas Water Heaters |
|||||||||
Top Vent Height A | N/A 51 in1295 mm | N/A 51 in1295 mm | N/A 51 in1295 mm | N/A 51 in1295 mm | N/A 73-1/4 in1861 mm | |||||
Jacket Diameter B | N/A 28-1/4 in718 mm | |||||||||
Vent Diameter C | N/A 6 in152 mm | N/A 6 in152 mm | N/A 6 in152 mm | N/A 6 in152 mm | N/A 8 in203 mm | |||||
Front Hot Water Connection D | N/A 35 in889 mm | N/A 35 in889 mm | N/A 35 in889 mm | N/A 35 in889 mm | N/A 54-1/8 in1375 mm | |||||
Floor to Gas Connection E | N/A 4-5/8 in117 mm | N/A 4-5/8 in117 mm | N/A 4-5/8 in117 mm | N/A 4-5/8 in117 mm | N/A 10-1/2 in267 mm | |||||
Front Cold Water Connection F | N/A 19-3/8 in492 mm | N/A 19-3/8 in492 mm | N/A 19-3/8 in492 mm | N/A 19-3/8 in492 mm | N/A 29 in737 mm | |||||
Floor to Top of Heater H | N/A 43-1/2 in1105 mm | N/A 43-1/2 in1105 mm | N/A 43-1/2 in1105 mm | N/A 43-1/2 in1105 mm | N/A 64-3/4 in1645 mm | |||||
Floor to Top Water Connection J | N/A | |||||||||
Water Connection | N/A 1-1/2 in38 mm | |||||||||
Water Connection Type (Imperial) | N/A Front | |||||||||
Water Connection Type (Metric) | N/A Front | |||||||||
Gas Connection Diameter | N/A 3/4 in19 mm | N/A 3/4 in19 mm | N/A 3/4 in19 mm | N/A 3/4 in19 mm | N/A 1 in25 mm | |||||
Relief Valve Opening | N/A 3/4 in19 mm | N/A 3/4 in19 mm | N/A 3/4 in19 mm | N/A 3/4 in19 mm | N/A 1 in25 mm | |||||
Standard Approximate Shipping Weight | N/A 438 lb199 kg | N/A 438 lb199 kg | N/A 438 lb199 kg | N/A 438 lb199 kg | N/A 665 lb302 kg | |||||
ASME Approximate Shipping Weight | N/A | N/A | N/A | N/A | N/A 720 lb327 kg | |||||
Type | N/A Natural Gas | N/A Liquid Propane Gas | N/A Natural Gas | N/A Liquid Propane Gas | N/A Natural Gas | |||||
Style | N/A Flue Damper Electronic Ignition | |||||||||
Size | N/A C | |||||||||
Model Type | N/A | N/A | N/A Low NOx Compliance | N/A Low NOx Compliance | N/A | |||||
Test Pressure | N/A 300 psi2068 kPa | |||||||||
Working Pressure | N/A 150 psi1034 kPa | |||||||||
Available Kits | N/A | N/A | N/A | N/A | N/A 239-81766-00 | |||||
Industry Standards | N/A AGA/CGA AHRI Certified® ANSI Standards Z-21.10.3 ASME Certified CSA® Certified NSF | |||||||||
General Information |
N/A
All gas water heaters are certified at 300 psi test pressure (2068 kPa) and 150 psi working pressure (1034 kPa). All models are design certified by CSA® International (formerly AGA/CGA), ANSI standard Z-21.10.3, for up to 180 ºF (82 ºC) application as an Automatic Storage Heater, and an Automatic Circulating Tank Heater. As an Automatic Storage Heater, all models are complete, self-contained water heating systems. It needs no separate storage tank, pump, wiring or elaborate piping network. When equipped with a mixing valve, it will supply 180 ºF (82 ºC) sanitizing and lower temperature general purpose hot water simultaneously. These models can be used either as a single unit or in multiples connected in series or parallel (recommended). Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement. |
|||||||||
Warranty |
N/A
|
|||||||||
Features |
N/A
The Commercial Flue Damper Models feature:
|
|||||||||
Note |
N/A
Fiberglass Insulation Amperage Draw = 0.5 for damper models/less than 4 for induced draft models Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed |
N/A
Fiberglass Insulation Amperage Draw = 0.5 for damper models/less than 4 for induced draft models Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed |
N/A
Fiberglass Insulation Amperage Draw = 0.5 for damper models/less than 4 for induced draft models Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed |
N/A
Fiberglass Insulation Amperage Draw = 0.5 for damper models/less than 4 for induced draft models Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed |
N/A
ASME Code Available Power Vent Kits Available Amperage Draw = 0.5 for damper models/less than 4 for induced draft models Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed |
|||||
|