Catalog
Unit of Measure
Items
Light Duty Commercial Electric Water Heaters

Light Duty Commercial Electric Water Heaters

Light Duty Commercial Electric Water Heaters

Light Duty Commercial Electric Water Heaters

Light Duty Commercial Electric Water Heaters

Light Duty Commercial Electric Water Heaters

Light Duty Commercial Electric Water Heaters

Light Duty Commercial Electric Water Heaters

Light Duty Commercial Electric Water Heaters

Light Duty Commercial Electric Water Heaters
Manufacturer N/A American Standard®
Capacity N/A 30 gal
Schematic N/A
Schematic Drawing for Light-Duty Commercial Electric Water Heaters
Jacket Diameter A N/A 18-1/4 in
Floor to Water Connection B N/A 48-3/4 in
Floor to Top of Heater C N/A 46 in
Floor to Side T and P D N/A 40-1/4 in
Water Spread E N/A 8 in
Standard Voltage N/A 240 V
Maximum Input Power N/A 12 kW
Standard Shipping Weight N/A 98 lb
Element Power N/A 1500 W N/A 2000 W N/A 2500 W N/A 3000 W N/A 3500 W
Recovery at 40 ºF Temperature Rise N/A N/A N/A N/A 31 gal/h N/A 36 gal/h
Recovery at 50 ºF Temperature Rise N/A N/A N/A N/A 25 gal/h N/A 29 gal/h
Recovery at 60 ºF Temperature Rise N/A N/A N/A N/A 20 gal/h N/A 24 gal/h
Recovery at 70 ºF Temperature Rise N/A N/A N/A N/A 18 gal/h N/A 20 gal/h
Recovery at 80 ºF Temperature Rise N/A N/A N/A N/A 15 gal/h N/A 18 gal/h
Recovery at 90 ºF Temperature Rise N/A N/A N/A N/A 14 gal/h N/A 16 gal/h
Recovery at 100 ºF Temperature Rise N/A N/A N/A N/A 12 gal/h N/A 14 gal/h
Full Load Current Single Phase 120 V N/A 12.5 A N/A 16.7 A N/A 20.8 A N/A 25 A N/A
Full Load Current Single Phase 208 V N/A 7.2 A N/A 9.6 A N/A 12 A N/A 14.4 A N/A 16.8 A
Full Load Current Single Phase 240 V N/A 6.3 A N/A 8.3 A N/A 10.4 A N/A 12.5 A N/A 14.6 A
Full Load Current Single Phase 277 V N/A 5.4 A N/A 7.2 A N/A 9 A N/A 10.8 A N/A 12.6 A
Full Load Current Single Phase 480 V N/A 3.1 A N/A 4.2 A N/A 5.2 A N/A 6.3 A N/A 7.3 A
Full Load Current Three Phase 208 V (All Terminals L1, L2, and L3) N/A N/A N/A N/A 14.4 A N/A
Full Load Current Three Phase 240 V (All Terminals L1, L2, and L3) N/A N/A N/A N/A 12.5 A N/A
Full Load Current Three Phase 480 V (All Terminals L1, L2, and L3) N/A N/A N/A N/A 6.3 A N/A
Full Load Current Three Phase 208 V (Terminal L3) N/A N/A N/A N/A 25 A N/A
Full Load Current Three Phase 240 V (Terminal L3) N/A N/A N/A N/A 21.7 A N/A
Full Load Current Three Phase 480 V (Terminal L3) N/A N/A N/A N/A 10.8 A N/A
Full Load Current Three Phase 208 V (Terminal L1 and L2) N/A N/A N/A N/A 14.4 A N/A
Full Load Current Three Phase 240 V (Terminal L1 and L2) N/A N/A N/A N/A 12.5 A N/A
Full Load Current Three Phase 480 V (Terminal L1 and L2) N/A N/A N/A N/A 6.3 A N/A
Operation Type N/A N/A N/A N/A Interlocking Operation Simultaneous Operation N/A
Voltage N/A 120 V208 V240 V277 V480 V N/A 120 V208 V240 V277 V480 V N/A 120 V208 V240 V277 V480 V N/A 120 V208 V240 V277 V480 V N/A 208 V240 V277 V480 V
Phase N/A Single N/A Single N/A Single N/A Single Three N/A Single
Test Pressure N/A 300 psi
Working Pressure N/A 150 psi
Size N/A C
Type N/A Electric
Model Type N/A Tall
Industry Standards N/A ANSI ASHRAE 90.1b-1992 C.E.C. Listed UL® 174
Features N/A
  • Surface Mount Thermostats - Fully automatic for temperature control.
  • Dual Heating Elements - Screw-in, direct immersion, 4500 watt, 240 volt incoloy heating elements for maximum efficiency. Available in 120, 208, 240, 277, & 480 voltages, single- or three-phase. Wattages available up to 12 KW.
  • Self-Cleaning - Turbulence inducing cold water inlet-tube engineered to diminish hard water area sediment deposits.
  • Non-CFC Foam Insulated - Full 2" foam insulation saves energy & reduces fuel costs by maximizing heat retention.
  • Heavy Gauge Steel Tank - For extra years of trouble-free service.
  • Glass-Lined Tank - Inner tank glass-lined with Dura-Glas™ & fired at 1600 ºF for optimum protection from the effects of corrosion.
  • Magnesium Anode Rod - To prolong tank life.
  • Electric Junction Box - For 1/2" or 3/4" conduit.
  • Factory Installed Dielectric Hot & Cold Water Connections - 3 4" NPT water connections to extend tank life & for easier installations.
  • Brass Drain Valve - Durable & to prevent unintentional breakage.
  • Factory Installed Heat Traps - Reduces standby heat loss in water piping.
  • Temperature & Pressure Relief Valve - Factory provided T & P Valve can be relocated from side to optional top opening.
  • Factory Installed Energy Cut-Off System - Manual reset energy cut-off prevents overheating.
Testing and Certifications N/A
  • Certified By Underwriters Laboratories - Listed to UL 174, meets or exceeds efficiency requirements of the Department of Energy, ASHRAE Standard 90.1 b-1992. National Appliance Energy Conservation Act, ANSI requirements, is CEC listed & tested in accordance with D.O.E. test procedures & all state energy efficiency standards
  • American Standard® Commercial Electric Water Heaters - are certified at 300 PSI test pressure & 150 PSI working pressure, & all tanks are 100% hydrostatically tested at the factory
  • UL Listed
Warranty N/A
  • 3-Year Limited Warranty - On Inner Glass-Lined Tank.
  • 1-Year Limited Warranty - On all Other Component Parts.
Note N/A These water heaters meet or exceed ASHRAE 90.1b-1992 standards and are listed with the California energy commission.