Catalog
Commercial Electric Water Heaters
American Standard® Electric Commercial Water Heaters
American Standard Commercial Electric Model CE-52-AS, CE-80-AS, and CE-120-AS are designed for point-of-use installations where large quantities of hot water are required on a commercial basis. Customary applications include industrial buildings, motels, hotels, schools, hospitals, restaurants, laundromats, car washes and multi-family developments.
Unit of Measure
Items |
/Asset/a1001.jpg CE-52-AS-6KW 52 Gallon Commercial Electric Water Heater |
/Asset/a1001.jpg CE-52-AS-9KW 52 Gallon Commercial Electric Water Heater |
/Asset/a1001.jpg CE-52-AS-12KW 52 Gallon Commercial Electric Water Heater |
/Asset/a1001.jpg CE-52-AS-15KW 52 Gallon Commercial Electric Water Heater |
/Asset/a1001.jpg CE-52-AS-18KW 52 Gallon Commercial Electric Water Heater |
|||||
Manufacturer | N/A American Standard® | |||||||||
Input Power | N/A 6 kW | N/A 9 kW | N/A 12 kW | N/A 15 kW | N/A 18 kW | |||||
Capacity | N/A 52 gal | |||||||||
Schematic |
N/A
Schematic Drawing for High Efficiency Series Commercial Electric Water Heaters |
|||||||||
Jacket Diameter A | N/A 24-3/4 in | |||||||||
Floor to Cold Water Inlet B | N/A 6-1/2 in | |||||||||
Floor to Top of Control Box C | N/A 46-9/16 in | |||||||||
Floor to PTR Valve D | N/A 44-3/8 in | |||||||||
Height to Top of Heater E | N/A 51-1/2 in | |||||||||
Floor to Hot Water Outlet F | N/A 54-1/4 in | |||||||||
Front Control Access Panel Depth | N/A 4-1/2 in | |||||||||
Water Connection | N/A 1-1/2 in | |||||||||
Approximate Shipping Weight | N/A 271 lb | |||||||||
Voltage | N/A 208 V240 V277 V480 V | |||||||||
Phase | N/A Single Three | |||||||||
Industry Standards | N/A ANSI 5 ASHRAE 90.1b-1992 CSA® Certified NSF UL® Listed | |||||||||
Number of Elements 208 V Single Phase (Fused Models) |
N/A 1 | N/A 3 | N/A 2 | N/A 3 | N/A 3 | |||||
Number of Elements 208 V Three Phase (Fused Models) |
N/A 3 | |||||||||
Number of Elements 240 V Single Phase (Fused Models) |
N/A 1 | N/A 3 | N/A 2 | N/A 3 | N/A 3 | |||||
Number of Elements 240 V Three Phase (Fused Models) |
N/A 3 | |||||||||
Number of Elements 227 V Single Phase (Fused Models) |
N/A 2 | N/A 3 | N/A 2 | N/A 3 | N/A 3 | |||||
Number of Elements 480 V Single Phase (Fused Models) |
N/A 1 | N/A 3 | N/A 2 | N/A 3 | N/A 3 | |||||
Number of Elements 480 V Three Phase (Fused Models) |
N/A 3 | |||||||||
Full Load Current Single Phase 208 V | N/A 28.8 A | N/A 42.2[2] A | N/A 57.6 A | N/A 72.1 A | N/A 86.5 A | |||||
Full Load Current Three Phase 208 V | N/A 16.6 A | N/A 25.0 A | N/A 33.3 A | N/A 41.6 A | N/A 50.0 A | |||||
Full Load Current Single Phase 240 V | N/A 25 A | N/A 37.5[2] A | N/A 50 A | N/A 62.5 A | N/A 75 A | |||||
Full Load Current Three Phase 240 V | N/A 14.4 A | N/A 21.6 A | N/A 28.9 A | N/A 36.1 A | N/A 43.4 A | |||||
Full Load Current Single Phase 277 V | N/A 21.6 A | N/A 32.4[2] A | N/A 43.3[2] A | N/A 54.1 A | N/A 64 A | |||||
Full Load Current Single Phase 480 V | N/A 12.5 A | N/A 18.7[2] A | N/A 25 A | N/A 31.2 A | N/A 37.5 A | |||||
Full Load Current Three Phase 480 V | N/A 7.2 A | N/A 10.8 A | N/A 14.4 A | N/A 18.0 A | N/A 21.6 A | |||||
Recovery at 40 ºF Temperature Rise | N/A 62 gal/h | N/A 93 gal/h | N/A 124 gal/h | N/A 155 gal/h | N/A 186 gal/h | |||||
Recovery at 50 ºF Temperature Rise | N/A 50 gal/h | N/A 74 gal/h | N/A 99 gal/h | N/A 124 gal/h | N/A 149 gal/h | |||||
Recovery at 60 ºF Temperature Rise | N/A 41 gal/h | N/A 62 gal/h | N/A 83 gal/h | N/A 103 gal/h | N/A 124 gal/h | |||||
Recovery at 70 ºF Temperature Rise | N/A 35 gal/h | N/A 53 gal/h | N/A 71 gal/h | N/A 89 gal/h | N/A 106 gal/h | |||||
Recovery at 80 ºF Temperature Rise | N/A 31 gal/h | N/A 47 gal/h | N/A 62 gal/h | N/A 78 gal/h | N/A 93 gal/h | |||||
Recovery at 90 ºF Temperature Rise | N/A 28 gal/h | N/A 41 gal/h | N/A 55 gal/h | N/A 69 gal/h | N/A 83 gal/h | |||||
Recovery at 100 ºF Temperature Rise | N/A 25 gal/h | N/A 37 gal/h | N/A 50 gal/h | N/A 62 gal/h | N/A 74 gal/h | |||||
Recovery at 120 ºF Temperature Rise | N/A 21 gal/h | N/A 31 gal/h | N/A 41 gal/h | N/A 52 gal/h | N/A 62 gal/h | |||||
Recovery at 140 ºF Temperature Rise | N/A 18 gal/h | N/A 27 gal/h | N/A 35 gal/h | N/A 44 gal/h | N/A 53 gal/h | |||||
Size | N/A C | |||||||||
Type | N/A Electric | |||||||||
Test Pressure | N/A 300 psi | |||||||||
Working Pressure | N/A 150 psi | |||||||||
Features |
N/A
|
|||||||||
Testing and Certifications |
N/A
|
|||||||||
Warranty |
N/A
|
|||||||||
Note |
N/A
American Standard reserves the right to make product changes and/or improvements without notice. These water heaters meet or exceed ASHRAE 90.1B-1992 standard and are listed with the california energy commission. Units with amperage draw of 48 amps or more require factory installed fusing. Thermostat settings range from 140 ºF to 180 ºF. Optional 80 ºF to 140 ºF. Living up to a higher standard. |
|||||||||
|