Catalog
Unit of Measure
Items
Conservationist® Induced Draft Low NOx Commercial Gas Water Heaters

Conservationist® Induced Draft Low NOx Commercial Gas Water Heaters

Conservationist® Induced Draft Low NOx Commercial Gas Water Heaters

Conservationist® Induced Draft Low NOx Commercial Gas Water Heaters
Manufacturer N/A A. O. Smith®
Schematic N/A
Schematic Drawing for Conservationist® Induced Draft Low NOx Gas Water Heaters
Dimension A N/A 65-5/16 in1684 mm N/A 71-1/4 in1810 mm
Dimension B N/A 58-1/2 in1486 mm N/A 66-1/2 in1689 mm
Dimension C N/A 29-5/8 in753 mm N/A 30-3/4 in781 mm
Dimension D N/A 25-3/8 in645 mm N/A 26-1/2 in673 mm
Dimension E N/A 15 in381 mm
Dimension F N/A 4 in102 mm
Dimension G N/A 14 in356 mm N/A 14 1/2 in356 mm
Dimension H N/A 16 in406 mm
Dimension J N/A 1-1/4 in32 mm
Dimension K N/A 1 in25 mm N/A 1-1/4 in32 mm
Dimension L N/A 1/2 in13 mm
Dimension M N/A 11-15/16 in303 mm
Capacity N/A 74 gal N/A 98 gal
Type N/A Liquid Propane Gas Natural Gas
Input Power N/A 80000 BTU/hr23.4 kW N/A 90000 BTU/hr26.4 kW
Recovery at 30 ºF Temperature Rise
N/A 258 gal/h N/A 291 gal/h
Recovery at 17 ºC Temperature Rise
N/A 973 L/h N/A 1104 L/h
Recovery at 36 ºF Temperature Rise
N/A 215 gal/h N/A 242 gal/h
Recovery at 20 ºC Temperature Rise
N/A 814 L/h N/A 915 L/h
Recovery at 40 ºF Degree Rise
N/A 193 gal/h N/A 218 gal/h
Recovery at 23 ºC Temperature Rise
N/A 731 L/h N/A 825 L/h
Recovery at 50 ºF Temperature Rise
N/A 155 gal/h N/A 175 gal/h
Recovery at 28 ºC Temperature Rise
N/A 585 L/h N/A 662 L/h
Recovery at 54 ºF Temperature Rise
N/A 143 gal/h N/A 162 gal/h
Recovery at 30 ºC Temperature Rise
N/A 541 L/h N/A 613 L/h
Recovery at 60 ºF Temperature Rise
N/A 130 gal/h N/A 145 gal/h
Recovery at 33 ºC Temperature Rise
N/A 490 L/h N/A 548 L/h
Recovery at 70 ºF Temperature Rise
N/A 111 gal/h N/A 125 gal/h
Recovery at 39 ºC Temperature Rise
N/A 419 L/h N/A 473 L/h
Recovery at 72 ºF Temperature Rise
N/A 108 gal/h N/A 121 gal/h
Recovery at 40 ºC Temperature Rise
N/A 407 L/h N/A 457 L/h
Recovery at 80 ºF Temperature Rise
N/A 97 gal/h N/A 109 gal/h
Recovery at 44 ºC Temperature Rise
N/A 368 L/h N/A 412 L/h
Recovery at 90 ºF Temperature Rise
N/A 86 gal/h N/A 97 gal/h
Recovery at 50 ºC Temperature Rise
N/A 324 L/h N/A 367 L/h
Recovery at 100 ºF Temperature Rise
N/A 77 gal/h N/A 87 gal/h
Recovery at 56 ºC Temperature Rise
N/A 293 L/h N/A 329 L/h
Recovery at 108 ºF Temperature Rise
N/A 71 gal/h N/A 81 gal/h
Recovery at 60 ºC Temperature Rise
N/A 269 L/h N/A 306 L/h
Recovery at 110 ºF Temperature Rise
N/A 70 gal/h N/A 79 gal/h
Recovery at 61 ºC Temperature Rise
N/A 264 L/h N/A 299 L/h
Recovery at 120 ºF Temperature Rise
N/A 65 gal/h N/A 73 gal/h
Recovery at 67 ºC Temperature Rise
N/A 245 L/h N/A 276 L/h
Recovery at 126 ºF Temperature Rise
N/A 62 gal/h N/A 69 gal/h
Recovery at 70 ºC Temperature Rise
N/A 233 L/h N/A 261 L/h
Recovery at 130 ºF Temperature Rise
N/A 60 gal/h N/A 67 gal/h
Recovery at 72 ºC Temperature Rise
N/A 225 L/h N/A 253 L/h
Recovery at 140 ºF Temperature Rise
N/A 55 gal/h N/A 62 gal/h
Recovery at 78 ºC Temperature Rise
N/A 209 L/h N/A 234 L/h
Manifold Pressure N/A For Liquid Propane Gas: 2.49 kPaFor Natural Gas: 1.12 kPaFor Liquid Propane Gas: 10 inWcFor Natural Gas: 4.5 inWc
Voltage N/A 120 V
Frequency N/A 60 Hz
Current N/A <5 A
Maximum Gas Supply Pressure N/A 14 inWc3.48 kPa
Minimum Supply Pressure for Natural Gas N/A 1.24 kPa5 in
Minimum Supply Pressure for Liquid Propane Gas N/A 11 inWc2.74 kPa
Industry Standards N/A ANSI Z-21.10.3 - CSA 4.3 ASHRAE/IESNA 90.1
Features N/A The BTN-80 and BTN-100 are equipped with a factory-mounted blower that is pre-wired. This blower produces a pre-ignition draft of make-up air prior to burner ignition and provides more efficient control of heat and helps ensure an adequate supply of make-up air. Prior to ignition, the control proves a working draft.

Factory-installed Blower
  • Control proves draft prior to ignition
  • No draft hood or barometric damper required
  • Blower is factory mounted with a 6-foot power cord: requires 120 V, 3 amp or less electrical system connection
Intelli-Vent™ Gas Control
  • Equipped with nearly indestructible silicon nitride hot surface igniter
  • Advanced electronics for more precise control of water temperature
  • Easy-to-understand system diagnostics
Rated as Category I Appliance
  • Category I appliance: uses standard metal, single-wall or "B"-type vent
  • Can be commonly vented with other Category I appliances
  • Vent connects directly to blower outlet
Fully Automatic Control System
  • Auto reset gas shutoff device prevents excessive water temperature
  • Adjustable thermostat with 120 to 180 ºF range
  • Gas pressure regulator
Factory Equipped With Dual Burners

Glass Lined Tank
  • Exclusive CoreGard™ anode rods with stainless steel core provide additional corrosion protection
Handhole Cleanout
  • Allows easy access to tank interior for cleaning
Conservationist® Btn Options
Optional Leg Kit To Meet Nsf Standard 5 (Part # 9006645005 BTN 80 & 100)

Intelli-Vent™ is a registered trademark of Emerson Electric Company.
Options N/A Conservationist® Btn Options
Optional Leg Kit to Meet NSF Standard 5 (Part # 9006645005 BTN 80 & 100)

Intelli-Vent™ is a registered trademark of Emerson Electric Company.
Testing and Certifications N/A CSA® Certified and ASME Rated T&P Relief Valve

Codes and Standards
  • Design-certified according to ANSI Z21.10.3-CSA® 4.3 standards governing storage-type water heaters
  • California Energy Commission
  • Meets the thermal efficiency and standby loss requirements of the U.S. Department of Energy and current edition of ASHRAE/IESNA 90.1
  • Design-certified by Underwriters Laboratories
  • Certified for use on combustible flooring
  • Complies with Texas Low Nox and Air Quality Management Districts with requirements of less than 40 ng/j
Warranty N/A
  • 3-Year Limited Tank Warranty.
Note N/A Note for Recovery:
Recovery capacity based on 80% thermal efficiency.

Note for Gas and Electrical Characteristics:
Minimum pressures must be maintained under both load and no load (static and dynamic) conditions.